Diffusion lung imaging with hyperpolarized gas MRI
DA Yablonskiy, AL Sukstanskii, JD Quirk - NMR in Biomedicine, 2017 - Wiley Online Library
Lung imaging using conventional 1H MRI presents great challenges because of the low
density of lung tissue, lung motion and very fast lung tissue transverse relaxation (typical T2 …
density of lung tissue, lung motion and very fast lung tissue transverse relaxation (typical T2 …
Lung morphometry using hyperpolarized 129Xe apparent diffusion coefficient anisotropy in chronic obstructive pulmonary disease
A Ouriadov, A Farag, M Kirby… - Magnetic resonance …, 2013 - Wiley Online Library
Purpose The goal of this work was to investigate lung morphological changes associated
with chronic obstructive pulmonary disease (COPD) using hyperpolarized 129Xe diffusion …
with chronic obstructive pulmonary disease (COPD) using hyperpolarized 129Xe diffusion …
Lung morphometry with hyperpolarized 129Xe: Theoretical background
AL Sukstanskii, DA Yablonskiy - Magnetic resonance in …, 2012 - Wiley Online Library
The 3He lung morphometry technique, based on MRI measurements of hyperpolarized 3He
gas diffusion in lung airspaces, provides unique information on the lung microstructure at the …
gas diffusion in lung airspaces, provides unique information on the lung microstructure at the …
Hyperpolarized 129Xe gas transfer MRI: the transition from 1.5T to 3T
Purpose Hyperpolarized 129Xe MRI depicting 3D ventilation, interstitial barrier uptake, and
transfer to red blood cells (RBCs) has emerged as a powerful new means of detecting …
transfer to red blood cells (RBCs) has emerged as a powerful new means of detecting …
Hyperpolarized 129Xe gas lung MRI–SNR and T2* comparisons at 1.5 T and 3 T
X Xu, G Norquay, SR Parnell, MH Deppe… - Magnetic resonance …, 2012 - Wiley Online Library
In this study, the signal‐to‐noise ratio of hyperpolarized 129Xe human lung magnetic
resonance imaging was compared at 1.5 T and 3 T. Experiments were performed at both B0 …
resonance imaging was compared at 1.5 T and 3 T. Experiments were performed at both B0 …
Signal‐to‐noise ratio, T2, and for hyperpolarized helium‐3 MRI of the human lung at three magnetic field strengths
Purpose To evaluate T2,, and signal‐to‐noise ratio (SNR) for hyperpolarized helium‐3
(3He) MRI of the human lung at three magnetic field strengths ranging from 0.43 T to 1.5 T …
(3He) MRI of the human lung at three magnetic field strengths ranging from 0.43 T to 1.5 T …
Probing lung microstructure with hyperpolarized 3He gradient echo MRI
AL Sukstanskii, JD Quirk, DA Yablonskiy - NMR in Biomedicine, 2014 - Wiley Online Library
In this paper we demonstrate that gradient echo MRI with hyperpolarized 3He gas can be
used for simultaneously extracting in vivo information about lung ventilation properties …
used for simultaneously extracting in vivo information about lung ventilation properties …
MRI acquisition techniques
JP Mugler Iii - Hyperpolarized and Inert Gas MRI, 2017 - Elsevier
Several characteristics of hyperpolarized gases relevant to the design of magnetic
resonance acquisitions differ substantially from those for water or lipid protons in biological …
resonance acquisitions differ substantially from those for water or lipid protons in biological …
Quantitative Hyperpolarized 129Xe Gas exchange MRI: Development and Applications
Z Wang - 2020 - search.proquest.com
Pulmonary diseases are one of the leading causes of death and contribute to major
healthcare cost in the United States. However, clinical treatment of these diseases has long …
healthcare cost in the United States. However, clinical treatment of these diseases has long …
Signal-to-noise ratio, T2, and.
Purpose: To evaluate T2, TÃ 2, and signal-to-noise ratio (SNR) for hyperpolarized helium-3
(3He) MRI of the human lung at three magnetic field strengths ranging from 0.43 T to 1.5 T …
(3He) MRI of the human lung at three magnetic field strengths ranging from 0.43 T to 1.5 T …