EPID‐based verification of the MLC performance for dynamic IMRT and VMAT

P Rowshanfarzad, M Sabet, MP Barnes… - Medical …, 2012 - Wiley Online Library
Purpose: In advanced radiotherapy treatments such as intensity modulated radiation therapy
(IMRT) and volumetric modulated arc therapy (VMAT), verification of the performance of the …

Detection and correction for EPID and gantry sag during arc delivery using cine EPID imaging

P Rowshanfarzad, M Sabet, DJ O'Connor… - Medical …, 2012 - Wiley Online Library
Purpose: Electronic portal imaging devices (EPIDs) have been studied and used for
pretreatment and in‐vivo dosimetry applications for many years. The application of EPIDs for …

[HTML][HTML] An EPID-based method for comprehensive verification of gantry, EPID and the MLC carriage positional accuracy in Varian linacs during arc treatments

P Rowshanfarzad, CK McGarry, MP Barnes, M Sabet… - Radiation …, 2014 - Springer
Background In modern radiotherapy, it is crucial to monitor the performance of all linac
components including gantry, collimation system and electronic portal imaging device …

Evaluation of the truebeam machine performance check (MPC) geometric checks for daily IGRT geometric accuracy quality assurance

MP Barnes, PB Greer - Journal of Applied Clinical Medical …, 2017 - Wiley Online Library
Abstract Machine Performance Check (MPC) is an automated and integrated image‐based
tool for verification of beam and geometric performance of the TrueBeam linac. The aims of …

Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary?

LMM Pudsey, G Biasi, A Ralston… - Journal of Applied …, 2022 - Wiley Online Library
Purpose Recently the use of linear accelerator (linac)‐based stereotactic radiosurgery
(SRS) has increased, including single‐isocenter multiple‐target SRS. The workload of …

On the selection of gantry and collimator angles for isocenter localization using Winston‐Lutz tests

W Du, JL Johnson, W Jiang… - Journal of applied …, 2016 - Wiley Online Library
In Winston‐Lutz (WL) tests, the isocenter of a linear accelerator (linac) is determined as the
intersection of radiation central axes (CAX) from multiple gantry, collimator, and couch …

SafetyNet: streamlining and automating QA in radiotherapy

SW Hadley, ML Kessler, DW Litzenberg… - Journal of applied …, 2016 - Wiley Online Library
Proper quality assurance (QA) of the radiotherapy process can be time‐consuming and
expensive. Many QA efforts, such as data export and import, are inefficient when done by …

Quantifying the gantry sag on linear accelerators and introducing an MLC‐based compensation strategy

W Du, S Gao, X Wang, RJ Kudchadker - Medical physics, 2012 - Wiley Online Library
Purpose: Gantry sag is one of the well‐known sources of mechanical imperfections that
compromise the spatial accuracy of radiation dose delivery. The objectives of this study were …

A comprehensive study of the mechanical performance of gantry, EPID and the MLC assembly in Elekta linacs during gantry rotation

P Rowshanfarzad, HL Riis… - The British journal of …, 2015 - academic.oup.com
Objective: In radiotherapy treatments, it is crucial to monitor the performance of linear
accelerator (linac) components, including gantry, collimation system and electronic portal …

Virtual EPID standard phantom audit (VESPA) for remote IMRT and VMAT credentialing

N Miri, J Lehmann, K Legge, P Vial… - Physics in Medicine & …, 2017 - iopscience.iop.org
A virtual EPID standard phantom audit (VESPA) has been implemented for remote auditing
in support of facility credentialing for clinical trials using IMRT and VMAT. VESPA is based …