A digital current control technique for grid-connected AC/DC converters used for energy storage systems

S Eren, M Pahlevani, A Bakhshai… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
This paper presents an advanced current controller for grid-connected bidirectional ac/dc
converters used for energy storage systems (ESSs). The proposed control scheme is …

New topology to reduce leakage current in three-phase transformerless grid-connected photovoltaic inverters

R Rahimi, B Farhangi… - 2016 7th Power Electronics …, 2016 - ieeexplore.ieee.org
Three phase converters are favorable for high power grid connected systems. In
photovoltaic (PV) application, it is possible to remove the transformer from the PV system in …

Optimal placement of additional switch in the photovoltaic single-phase grid-connected transformerless full bridge inverter for reducing common mode leakage current

R Rahimi, E Afshari, B Farhangi… - 2015 IEEE Conference …, 2015 - ieeexplore.ieee.org
Single phase converters are popular for grid connected applications at low power. In
photovoltaic (PV) application, it is possible to remove the transformer from the PV system in …

Control strategy without phase‐locked loop based on coordinate transformation for three‐phase AC/DC converter

X Zheng, L Xiao, Z Wang, Y Lei… - IET Power Electronics, 2015 - Wiley Online Library
A novel control strategy without phase‐locked loop (PLL) for the three‐phase AC/DC
converter is proposed in this study. There is no need to detect the phase angle of the grid …

Grid-connected control strategy of five-level inverter based on passive EL model

T Li, Q Cheng, W Sun, L Chen - Energies, 2017 - mdpi.com
At present, the research on five-level inverters mainly involves the modulation algorithm and
topology, and few articles study the five-level inverter from the control strategy. In this paper …

Topology and control strategy for accelerated lifetime test setup of DC-link capacitor of wind turbine converter

Y Ko, H Jedtberg, G Buticchi… - 2016 IEEE Applied …, 2016 - ieeexplore.ieee.org
Back-to-back converters for wind turbine systems (WTS) feature capacitors in the DC-link to
maintain a stable DC-link voltage and to decouple the generator from the grid. Electrolytic …

Comparative analysis of LCL filter with active and passive damping methods for grid-interactive inverter system

ML Sowjanya, BC Babu - Proceedings of the 2014 IEEE …, 2014 - ieeexplore.ieee.org
This paper presents the control strategy for a three-phase LCL-filter type based grid
connected inverter system for photovoltaic (PV) applications. The control strategy proposed …

Parameter co-design of active damping loop and grid current controller for a 3-phase LCL-filtered grid-connected inverter

J Lyu, Y Yan, F Wu, Z Sun, A Farooq, W Xu - International Journal of …, 2021 - Elsevier
Under non-ideal grid conditions, especially the harmonic grid condition, the proportional
resonant controller with multiple harmonic resonant controllers (HR-PR controller) is …

Simplified controller design method for digitally controlled LCL-type PWM converter with multi-resonant quasi-PR controller and capacitor-current-feedback active …

Y Lyu, H Lin - Journal of Power Electronics, 2014 - koreascience.kr
To track the sinusoidal current under stationary frame and suppress the effects of low-order
grid harmonics, the multi-resonant quasi-proportional plus resonant (PR) controller has …

A novel nonlinear current control technique for a grid-connected DC/AC inverter used in renewable energy power conditioning systems

S Eren, A Bakhshai, P Jain - 2014 IEEE 36th International …, 2014 - ieeexplore.ieee.org
Harvesting renewable energies is the solution to the global energy crisis. The performance
of the grid-connected voltage source inverter (VSI) with an LCL-filter, used for renewable …