Heat transfer in a U-bend pipe flow at supercritical pressure
T You, Y Pan, Y Zhai, H Wang, Z Li - International Journal of Heat and Mass …, 2022 - Elsevier
U-bend is widely used as a pipe fitting in heat exchangers, but the flow and heat transfer of
supercritical fluid in and following a U-bend have not been well understood yet. This work …
supercritical fluid in and following a U-bend have not been well understood yet. This work …
A non-invasive measurement method of pipeline flow rate based on dual FBG sensors
C Li, MY Liu, H Song, XL Yang, YH Wu - IEEE Sensors Journal, 2022 - ieeexplore.ieee.org
Combining fiber Bragg grating (FBG) sensors and finite element simulation analysis, an
online monitoring method for non-invasive distributed flow velocity in pipelines has been …
online monitoring method for non-invasive distributed flow velocity in pipelines has been …
Influence of elbow curvature on flow and turbulence structure through a 90° elbow
Y Ikarashi, T Uno, T Yamagata, N Fujisawa - Nuclear Engineering and …, 2018 - Elsevier
The influence of elbow curvature on the flow field of a 90° elbow was studied experimentally
to understand the flow and turbulence structure in the elbow using planar and stereo particle …
to understand the flow and turbulence structure in the elbow using planar and stereo particle …
PSO-tuned support vector machine metamodels for assessment of turbulent flows in pipe bends
Purpose Computational fluid dynamics (CFD) technique is the most commonly used
numerical approach to simulate fluid flow behaviour. Owing to its computationally, cost …
numerical approach to simulate fluid flow behaviour. Owing to its computationally, cost …
An LES study of secondary motion and wall shear stresses in a pipe bend
Large-eddy simulations (LES) of a single-phase, turbulent flow in a 90 pipe bend are
performed at three Reynolds numbers (5300, 27 000, and 45 000) to investigate the …
performed at three Reynolds numbers (5300, 27 000, and 45 000) to investigate the …
Numerical study of elbow corrosion in the presence of sodium chloride, calcium chloride, naphthenic acids, and sulfur in crude oil
M Meriem-Benziane, B Bou-Said… - Journal of Petroleum …, 2021 - Elsevier
During the crude oil refining process, the piping system suffers a lot of corrosion damage at
the elbows due to complex chemical reactions. This work aimed to investigate the effects of …
the elbows due to complex chemical reactions. This work aimed to investigate the effects of …
Ionic liquids with carboxylic-acid-derived anions evaluated as corrosion inhibitors under dynamic conditions
NV Likhanova, P Arellanes-Lozada… - International Journal of …, 2019 - Elsevier
The present work deals with the evaluation of three novel ionic liquids (ILs): triethylmethyl
ammonium laurate (TAL), triethylmethyl ammonium anthranilate (TAA) and triethylmethyl …
ammonium laurate (TAL), triethylmethyl ammonium anthranilate (TAA) and triethylmethyl …
Comparative study of mass transfer distributions and oil-flow visualizations with image analysis on long and short 90° elbows
N Fujisawa, T Takizawa, T Yamagata - Experimental Thermal and Fluid …, 2021 - Elsevier
To understand the mass transfer mechanism of 90° elbows, a comparative study of mass
transfer measurements and oil-flow visualization with image analysis is carried out for long …
transfer measurements and oil-flow visualization with image analysis is carried out for long …
FBG-based nonintrusive monitoring method for the impact force on 90° pipe elbow
MY Liu, XL Yang, H Song, F Zhou… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
Elbow pipe is one of the components in pipeline transportation. The impact force caused by
the liquid flow in the pipe elbow produces the strain on the wall. So, the monitoring of impact …
the liquid flow in the pipe elbow produces the strain on the wall. So, the monitoring of impact …
Mass transfer measurements and flow separation behavior in a 90 short elbow
Y Ikarashi, N Fujisawa - International Journal of Heat and Mass Transfer, 2019 - Elsevier
The mass transfer distribution and flow separation behavior in a 90° short elbow (radius to
diameter ratio 1.0) were investigated experimentally in the Reynolds number range Re=(3 …
diameter ratio 1.0) were investigated experimentally in the Reynolds number range Re=(3 …