Base-isolation of a hospital pavilion against in-plane-out-of-plane seismic collapse of masonry infills

F Mazza - Engineering Structures, 2021 - Elsevier
The in-plane (IP) and out-of-plane (OOP) seismic collapse of masonry infills (MIs) may
induce devastating economic and social consequences for public buildings such as …

Isolation performance of a small modular reactor using 1D periodic foundation

C Zhao, C Zeng, W Witarto, H wen Huang, J Dai… - Engineering …, 2021 - Elsevier
Photonic crystals or man-made periodic materials own band gap characteristics, which can
block the elastic wave propagate through the structure and can be used to mitigate the …

Development of a new base isolation system using the concept of metamaterials

MN Masoom, I Badar, RA Khushnood, FA Najam… - Engineering …, 2023 - Elsevier
Metamaterials are making a breakthrough in seismic wave manipulation with their ability to
yield wave filtration properties that cannot be realized inherently through conventional …

Magnetic damped links to reduce internal seismic pounding in base-isolated buildings

F Mazza, R Labernarda - Bulletin of Earthquake Engineering, 2020 - Springer
A limited gap between closely spaced structural parts may induce internal pounding in
seismically isolated structures, because of notable displacement at the level of the isolation …

Analysis of random wind-induced response of isolation structure with viscoelastic damper and TMD

J Ma, W Zou, G Bai - Journal of Wind Engineering and Industrial …, 2022 - Elsevier
The analysis method of wind vibration response of the seismically isolated structure with
viscoelastic damper and tuned mass damper (TMD) under Davenport wind load was studied …

Influence of isolator properties and earthquake characteristics on the seismic behavior of RC structure equipped with quintuple friction pendulum bearings

A Habib, U Yildirim - International Journal of Structural Stability and …, 2023 - World Scientific
Indeed, base isolation systems have gained significant attention from researchers and
designers over the last few decades. Within this context, various technologies were …

Seismic collision potential of adjacent base-isolated buildings with corridor bridges subjected to bidirectional near-fault pulse-like ground motions

K Dai, X Luo, Y Lu, B Li, J Zhong, S Zhang… - Soil Dynamics and …, 2020 - Elsevier
Adjacent base-isolated buildings with corridor bridges have a large seismic displacement
demand in their isolation layer, and therefore are prone to collision. Moreover, seismic wave …

Seismic performance and optimization design of a Post-installed Elevator Shear Wall structure

Y Chen, L Shen, M Wen, B Chen, J Jiang - Buildings, 2023 - mdpi.com
Post-installed elevator projects have grown significantly in recent years in response to the
problem of insufficient vertical traffic capacity in existing buildings, but research on the …

[PDF][PDF] Influence of earthquake parameters on the bi-directional behavior of base isolation systems

D Abed, J Al Thawabteh, Y Alzubi… - Civil Engineering …, 2022 - researchgate.net
The introduction and development of the base isolation systems, especially the friction
isolator device, were done recently to improve the capacity of adaptive behavior. The …

[PDF][PDF] Efficiency of friction pendulum bearings in vertically irregular structures subjected to various types of earthquakes

JG Al Adwan, S Al Kasassbeh… - Civil Engineering …, 2022 - academia.edu
The attention towards seismic mitigation using passive control systems has increased
significantly over the last few decades to reduce earthquake demands and achieve the …