Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …
Review of fast Monte Carlo codes for dose calculation in radiation therapy treatment planning
K Jabbari - Journal of Medical Signals & Sensors, 2011 - journals.lww.com
An important requirement in radiation therapy is a fast and accurate treatment planning
system. This system, using computed tomography (CT) data, direction, and characteristics of …
system. This system, using computed tomography (CT) data, direction, and characteristics of …
[PDF][PDF] DOSXYZnrc users manual
B Walters, I Kawrakow, DWO Rogers - Nrc Report Pirs, 2005 - nrc-cnrc.github.io
DOSXYZnrc is an EGSnrc-based Monte Carlo simulation code for calculating dose
distributions in a rectilinear voxel phantom and is based directly on the DOSXYZ code …
distributions in a rectilinear voxel phantom and is based directly on the DOSXYZ code …
A Monte Carlo pencil beam scanning model for proton treatment plan simulation using GATE/GEANT4
L Grevillot, D Bertrand, F Dessy, N Freud… - Physics in Medicine & …, 2011 - iopscience.iop.org
This work proposes a generic method for modeling scanned ion beam delivery systems,
without simulation of the treatment nozzle and based exclusively on beam data library (BDL) …
without simulation of the treatment nozzle and based exclusively on beam data library (BDL) …
Efficiency improvements for ion chamber calculations in high energy photon beams
J Wulff, K Zink, I Kawrakow - Medical physics, 2008 - Wiley Online Library
This article presents the implementation of several variance reduction techniques that
dramatically improve the simulation efficiency of ion chamber dose and perturbation factor …
dramatically improve the simulation efficiency of ion chamber dose and perturbation factor …
A free database of radionuclide voxel S values for the dosimetry of nonuniform activity distributions
N Lanconelli, M Pacilio, SL Meo, F Botta… - Physics in Medicine …, 2012 - iopscience.iop.org
The increasing availability of SPECT/CT devices with advanced technology offers the
opportunity for the accurate assessment of the radiation dose to the biological target volume …
opportunity for the accurate assessment of the radiation dose to the biological target volume …
Simulation of a 6 MV Elekta Precise Linac photon beam using GATE/GEANT4
L Grevillot, T Frisson, D Maneval, N Zahra… - Physics in Medicine …, 2011 - iopscience.iop.org
Abstract The GEANT4-based GATE Monte Carlo (MC) platform was initially focused on PET
and SPECT simulations. The new release v6. 0 (February 2010) proposes new tools …
and SPECT simulations. The new release v6. 0 (February 2010) proposes new tools …
Hypoxia-driven adenosine accumulation: a crucial microenvironmental factor promoting tumor progression
P Vaupel, A Mayer - Oxygen Transport to Tissue XXXVII, 2016 - Springer
Systematic studies on the oxygenation status of solid tumors have shown that the
development of hypoxic/anoxic tissue subvolumes is a pathophysiological trait in a wide …
development of hypoxic/anoxic tissue subvolumes is a pathophysiological trait in a wide …
An automated voxelized dosimetry tool for radionuclide therapy based on serial quantitative SPECT/CT imaging
Purpose: To create an accurate map of the distribution of radiation dose deposition in
healthy and target tissues during radionuclide therapy. Methods: Serial quantitative …
healthy and target tissues during radionuclide therapy. Methods: Serial quantitative …
Monte Carlo based, patient‐specific RapidArc QA using Linac log files
T Teke, AM Bergman, W Kwa, B Gill, C Duzenli… - Medical …, 2010 - Wiley Online Library
Purpose A Monte Carlo (MC) based QA process to validate the dynamic beam delivery
accuracy for Varian RapidArc™(Varian Medical Systems, Palo Alto, CA) using Linac delivery …
accuracy for Varian RapidArc™(Varian Medical Systems, Palo Alto, CA) using Linac delivery …