Endothelial shear stress in the evolution of coronary atherosclerotic plaque and vascular remodelling: current understanding and remaining questions

JJ Wentzel, YS Chatzizisis, FJH Gijsen… - Cardiovascular …, 2012 - academic.oup.com
The heterogeneity of plaque formation, the vascular remodelling response to plaque
formation, and the consequent phenotype of plaque instability attest to the extraordinarily …

[HTML][HTML] Intravascular hemodynamics and coronary artery disease: New insights and clinical implications

M Zaromytidou, G Siasos, AU Coskun, M Lucier… - Hellenic Journal of …, 2016 - Elsevier
Intravascular hemodynamics and coronary artery disease: New insights and clinical
implications - ScienceDirect Skip to main contentSkip to article Elsevier logo Journals & …

Fabrication of rigid and flexible refractive-index-matched flow phantoms for flow visualisation and optical flow measurements

PH Geoghegan, NA Buchmann, CJT Spence… - Experiments in …, 2012 - Springer
A method for the construction of both rigid and compliant (flexible) transparent flow
phantoms of biological flow structures, suitable for PIV and other optical flow methods with …

Unsteady blood flow and mass transfer of a human left coronary artery bifurcation: FSI vs. CFD

M Malvè, A García, J Ohayon, MA Martínez - … communications in heat and …, 2012 - Elsevier
In this study, a Fluid Solid Interaction analysis (FSI) of a computerized tomography (CT) scan
reconstructed left coronary artery was performed. The arterial wall was modeled as an …

Patient-specific computational fluid dynamics: structured mesh generation from coronary angiography

G De Santis, P Mortier, M De Beule, P Segers… - Medical & biological …, 2010 - Springer
Patient-specific simulations are widely used to investigate the local hemodynamics within
realistic morphologies. However, pre-processing and mesh generation are time consuming …

Accurate and reproducible reconstruction of coronary arteries and endothelial shear stress calculation using 3D OCT: comparative study to 3D IVUS and 3D QCA

K Toutouzas, YS Chatzizisis, M Riga, A Giannopoulos… - Atherosclerosis, 2015 - Elsevier
Abstract Background Geometrically-correct 3D OCT is a new imaging modality with the
potential to investigate the association of local hemodynamic microenvironment with OCT …

Optical coherence tomography for patient-specific 3D artery reconstruction and evaluation of wall shear stress in a left circumflex coronary artery

LM Ellwein, H Otake, TJ Gundert, BK Koo… - Cardiovascular …, 2011 - Springer
Image-based computational models for quantifying hemodynamic indices in stented
coronary arteries often employ biplane angiography and intravascular ultrasound for 3D …

[HTML][HTML] Coronary computed tomography angiography based assessment of endothelial shear stress and its association with atherosclerotic plaque distribution in-vivo

H Hetterich, A Jaber, M Gehring, A Curta, F Bamberg… - PLoS …, 2015 - journals.plos.org
Purpose The relationship between low endothelial shear stress (ESS) and coronary
atherosclerosis is well established. ESS assessment so far depended on invasive …

Synthetic database of aortic morphometry and hemodynamics: overcoming medical imaging data availability

B Thamsen, P Yevtushenko… - … on Medical Imaging, 2021 - ieeexplore.ieee.org
Modeling of hemodynamics and artificial intelligence have great potential to support clinical
diagnosis and decision making. While hemodynamics modeling is extremely time-and …

[HTML][HTML] Vascular corrosion casting: analyzing wall shear stress in the portal vein and vascular abnormalities in portal hypertensive and cirrhotic rodents

C Van Steenkiste, B Trachet, C Casteleyn… - Laboratory …, 2010 - nature.com
Vascular corrosion casting is an established method of anatomical preparation that has
recently been revived and has proven to be an excellent tool for detailed three-dimensional …