Compliant liquid dampers-inerter for mitigating wind-, wave-, and earthquake-induced vibrations of monopile offshore wind turbines
This work explores the possibility of installing compliant liquid dampers-inerter (CLDI) on
monopile offshore wind turbines (OWTs) for controlling combined vibrations from wind …
monopile offshore wind turbines (OWTs) for controlling combined vibrations from wind …
Pendulum-type tuned tandem mass dampers-inerters for crosswind response control of super-tall buildings
C Li, H Pan, L Cao - Journal of Wind Engineering and Industrial …, 2024 - Elsevier
In the present study, the pendulum-type tuned tandem mass dampers-inerters (PTTMDI) is
proposed to control the crosswind-induced dynamic responses in super-tall buildings. This …
proposed to control the crosswind-induced dynamic responses in super-tall buildings. This …
Tuned mass damper inerter for seismic control of multi-story buildings: Ten years since inception
The tuned mass damper inerter (TMDI), devised by combining a conventional tuned mass
damper (TMD) with an inerter, is believed to be a significant advancement in the realm of …
damper (TMD) with an inerter, is believed to be a significant advancement in the realm of …
Inerter-based tuned mass dampers for response control of multi-degree-of-freedom structures subjected to wind and earthquake excitations
The present work explores the utilization of the tuned mass damper-inerter (TMDI) in
controlling the structural response subjected to wind and earthquake excitations. An …
controlling the structural response subjected to wind and earthquake excitations. An …
Near-Fault Earthquake-Induced Vibration Control of a Supertall Benchmark Building Using an Inerter-Assisted Compliant Liquid Damper
To exploit the potential of liquid dampers for vibration control of supertall buildings, it is
essential to install sizable liquid tanks at the top of the building to provide a substantial value …
essential to install sizable liquid tanks at the top of the building to provide a substantial value …
Response mitigation of offshore wind turbine towers using negative stiffness amplifying compliant liquid dampers-inerter exposed to wind waves and earthquakes
A Das - Ocean Engineering, 2025 - Elsevier
The efficacy of compliant liquid dampers-inerter (CLDI) has been proven to improve the
dynamic response of monopile offshore wind turbine towers (MOWTT). The benefit of a …
dynamic response of monopile offshore wind turbine towers (MOWTT). The benefit of a …
Performance comparison of linear and nonlinear compliant liquid dampers-inerter in controlling across-wind response of benchmark tall building
The potential of compliant liquid dampers-inerter (CLDI) for response control of tall
buildings, capitalizing on the mass amplification property of the inerter, has been explored …
buildings, capitalizing on the mass amplification property of the inerter, has been explored …