Compliant liquid dampers-inerter for mitigating wind-, wave-, and earthquake-induced vibrations of monopile offshore wind turbines

A Das, H Ding - Ocean Engineering, 2024 - Elsevier
This work explores the possibility of installing compliant liquid dampers-inerter (CLDI) on
monopile offshore wind turbines (OWTs) for controlling combined vibrations from wind …

Pendulum-type tuned tandem mass dampers-inerters for crosswind response control of super-tall buildings

C Li, H Pan, L Cao - Journal of Wind Engineering and Industrial …, 2024 - Elsevier
In the present study, the pendulum-type tuned tandem mass dampers-inerters (PTTMDI) is
proposed to control the crosswind-induced dynamic responses in super-tall buildings. This …

Tuned mass damper inerter for seismic control of multi-story buildings: Ten years since inception

T Konar, AD Ghosh - Structures, 2024 - Elsevier
The tuned mass damper inerter (TMDI), devised by combining a conventional tuned mass
damper (TMD) with an inerter, is believed to be a significant advancement in the realm of …

Inerter-based tuned mass dampers for response control of multi-degree-of-freedom structures subjected to wind and earthquake excitations

A Das, A Banerjee, DR Sahoo… - Structure and …, 2024 - Taylor & Francis
The present work explores the utilization of the tuned mass damper-inerter (TMDI) in
controlling the structural response subjected to wind and earthquake excitations. An …

Near-Fault Earthquake-Induced Vibration Control of a Supertall Benchmark Building Using an Inerter-Assisted Compliant Liquid Damper

T Konar, A Das, AD Ghosh - ASCE-ASME Journal of Risk and …, 2024 - ascelibrary.org
To exploit the potential of liquid dampers for vibration control of supertall buildings, it is
essential to install sizable liquid tanks at the top of the building to provide a substantial value …

Response mitigation of offshore wind turbine towers using negative stiffness amplifying compliant liquid dampers-inerter exposed to wind waves and earthquakes

A Das - Ocean Engineering, 2025 - Elsevier
The efficacy of compliant liquid dampers-inerter (CLDI) has been proven to improve the
dynamic response of monopile offshore wind turbine towers (MOWTT). The benefit of a …

Performance comparison of linear and nonlinear compliant liquid dampers-inerter in controlling across-wind response of benchmark tall building

A Das, A Banerjee, DR Sahoo, V Matsagar - Journal of Building …, 2024 - Elsevier
The potential of compliant liquid dampers-inerter (CLDI) for response control of tall
buildings, capitalizing on the mass amplification property of the inerter, has been explored …