[HTML][HTML] Microfabricated reference electrodes and their biosensing applications
MW Shinwari, D Zhitomirsky, IA Deen… - Sensors, 2010 - mdpi.com
Over the past two decades, there has been an increasing trend towards miniaturization of
both biological and chemical sensors and their integration with miniaturized sample pre …
both biological and chemical sensors and their integration with miniaturized sample pre …
State-of-the-art lab chip sensors for environmental water monitoring
As a result of increased water demand and water pollution, both surface water and
groundwater quantity and quality are of major concern worldwide. In particular, the presence …
groundwater quantity and quality are of major concern worldwide. In particular, the presence …
A reference electrode based on polyvinyl butyral (PVB) polymer for decentralized chemical measurements
T Guinovart, GA Crespo, FX Rius, FJ Andrade - Analytica chimica acta, 2014 - Elsevier
A new solid-state reference electrode using a polymeric membrane of polyvinyl butyral
(PVB), Ag/AgCl and NaCl to be used in decentralized chemical measurements is presented …
(PVB), Ag/AgCl and NaCl to be used in decentralized chemical measurements is presented …
[HTML][HTML] A state-of-the-art review on Ag/AgCl ion-selective electrode used for non-destructive chloride detection in concrete
The accurate measurement of chloride content in concrete is of great importance, because
chloride-initiated corrosion of the reinforcement significantly influences the durability of …
chloride-initiated corrosion of the reinforcement significantly influences the durability of …
Relationship between microstructure of AgCl film and electrochemical behavior of Ag| AgCl electrode for chloride detection
The electrochemical behavior of Ag| AgCl electrode for chloride detection is closely related
to the microstructure of AgCl film on the electrode surface. In this study, the surface …
to the microstructure of AgCl film on the electrode surface. In this study, the surface …
Development and evaluation of an ultralow-noise sensor system for marine electric field measurements
Z Wang, M Deng, K Chen, M Wang, Q Zhang… - Sensors and Actuators A …, 2014 - Elsevier
In this paper, we describe the development of an ultralow-noise sensor system consisting of
non-polarizable Ag/AgCl electrodes and a chopper amplifier for detecting marine electric …
non-polarizable Ag/AgCl electrodes and a chopper amplifier for detecting marine electric …
A highly sensitive, long-time stable Ag/AgCl ultra-micro sensor for in situ monitoring chloride ions inside the crevice using SECM
H Zhang, HR Yuan, ZJ Zhu, QH Zhang, YH Bai… - Talanta, 2024 - Elsevier
Tracking the variation of Cl− timely within the crevice is of great significance for
comprehending the dynamic mechanism of crevice corrosion. The reported chloride ion …
comprehending the dynamic mechanism of crevice corrosion. The reported chloride ion …
Molecular dynamics study of the electrical double layer at silver chloride− electrolyte interfaces
Molecular dynamics simulations of the electrical double layer at AgCl− aqueous electrolyte
(KCl) interfaces are presented, accompanied by a new force field and properties of bulk …
(KCl) interfaces are presented, accompanied by a new force field and properties of bulk …
Reference electrodes for aqueous solutions
P Spitzer, S Wunderli, K Maksymiuk… - Handbook of Reference …, 2013 - Springer
The standard hydrogen electrode (SHE) acts as a primary reference in electrochemistry. The
standard potentials of all other reference electrodes are linked to that of the SHE at the same …
standard potentials of all other reference electrodes are linked to that of the SHE at the same …
Research of sensing characteristic and dynamic measurement of graphene oxides modified flexible arrayed RuO2 chlorine ion sensor
SC Tseng, TY Wu, JC Chou, YH Liao, CH Lai… - Materials Research …, 2018 - Elsevier
In this study, we used the graphene oxide (GO) solution, in which the concentration was from
0.005 wt% to 0.500 wt%, to modify the flexible arrayed ruthenium dioxide (RuO 2) chlorine …
0.005 wt% to 0.500 wt%, to modify the flexible arrayed ruthenium dioxide (RuO 2) chlorine …