Cavity ring-down spectroscopy: recent technological advancements, techniques, and applications
A Maity, S Maithani, M Pradhan - Analytical chemistry, 2020 - ACS Publications
Cavity ring-down spectroscopy (CRDS), first pioneered in 1988 by O'Keefe and Deacon, 1
has evolved into a newgeneration, precision spectroscopy in recent years and subsequently …
has evolved into a newgeneration, precision spectroscopy in recent years and subsequently …
Cavity ring-down spectroscopy: recent technological advances and applications
A Maity, S Maithani, M Pradhan - Molecular and laser spectroscopy, 2020 - Elsevier
Cavity ring-down spectroscopy (CRDS) is a direct quantitative absorption technique that
utilizes an enhanced light-matter interaction length inside a high-finesse optical resonator …
utilizes an enhanced light-matter interaction length inside a high-finesse optical resonator …
SI-traceable molecular transition frequency measurements at the 10−12 relative uncertainty level
Accurate and spectroscopic measurements of molecular transition frequencies are
increasingly being employed in a variety of rigorous tests of physics, including the validity of …
increasingly being employed in a variety of rigorous tests of physics, including the validity of …
Laser-based primary thermometry: a review
Laser-based primary thermometry was initiated almost 15 years ago by the proposal to
determine the absolute temperature of a gas at thermodynamic equilibrium through the …
determine the absolute temperature of a gas at thermodynamic equilibrium through the …
Comb-locked frequency-swept synthesizer for high precision broadband spectroscopy
Frequency combs have made optical metrology accessible to hundreds of laboratories
worldwide and they have set new benchmarks in multi-species trace gas sensing for …
worldwide and they have set new benchmarks in multi-species trace gas sensing for …
Cavity-enhanced saturated absorption spectroscopy of the (30012)−(00001) band of 12C16O2
Y Tan, YR Xu, TP Hua, AW Liu, J Wang… - The Journal of …, 2022 - pubs.aip.org
The (30012)←(00001) band of 12 C 16 O 2 in the 1.6 μm region is used for satellite
observation of carbon dioxide in the Earth's atmosphere. Here, we report a Doppler-free …
observation of carbon dioxide in the Earth's atmosphere. Here, we report a Doppler-free …
New frontiers in modern resonator spectroscopy
MA Koshelev, II Leonov, EA Serov… - IEEE Transactions …, 2018 - ieeexplore.ieee.org
New opportunities due to the advancements in the techniques and methods of broadband
resonator spectroscopy in the millimeter and submillimeter range (also known as the …
resonator spectroscopy in the millimeter and submillimeter range (also known as the …
Cavity-ring-down Doppler-broadening primary thermometry
A step forward in Doppler-broadening thermometry is demonstrated using a comb-assisted
cavity-ring-down spectroscopic approach applied to an isolated near-infrared line of carbon …
cavity-ring-down spectroscopic approach applied to an isolated near-infrared line of carbon …
Accurate deuterium spectroscopy and comparison with ab initio calculations
We present accurate measurements of the quadrupole S (3) and S (4) transitions of the D 2
2− 0 band. Self-perturbed spectra were collected in a wide pressure range with a cavity ring …
2− 0 band. Self-perturbed spectra were collected in a wide pressure range with a cavity ring …
Line parameters of the P-branch of (30012)←(00001) 12C16O2 band measured by comb-assisted, Pound-Drever-Hall locked cavity ring-down spectrometer
R Guo, J Teng, H Dong, T Zhang, D Li… - Journal of Quantitative …, 2021 - Elsevier
This article presents an accurate measurement of line parameters for the P-branch of
(30012)←(00001) 12 C 16 O 2 band with rotational quantum number extending to-72. The …
(30012)←(00001) 12 C 16 O 2 band with rotational quantum number extending to-72. The …