Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging
E Roncali, MA Mosleh-Shirazi… - Physics in Medicine & …, 2017 - iopscience.iop.org
Computational modelling of radiation transport can enhance the understanding of the
relative importance of individual processes involved in imaging systems. Modelling is a …
relative importance of individual processes involved in imaging systems. Modelling is a …
Modeling granular phosphor screens by Monte Carlo methods
The intrinsic phosphor properties are of significant importance for the performance of
phosphor screens used in medical imaging systems. In previous analytical‐theoretical and …
phosphor screens used in medical imaging systems. In previous analytical‐theoretical and …
MANTIS: combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems
A Badano, J Sempau - Physics in Medicine & Biology, 2006 - iopscience.iop.org
We describe MANTIS (Monte carlo x-rAy electroN opTical Imaging Simulation), a tool for
simulating imaging systems that tracks x-rays, electrons and optical photons in arbitrary …
simulating imaging systems that tracks x-rays, electrons and optical photons in arbitrary …
Comparison of CsI:Tl and Gd2O2S:Tb indirect flat panel detector x‐ray imaging performance in front‐ and back‐irradiation geometries
A Howansky, A Mishchenko, AR Lubinsky… - Medical …, 2019 - Wiley Online Library
Purpose The detective quantum efficiency (DQE) of indirect flat panel detectors (I‐FPDs) is
limited at higher x‐ray energies (eg, 100–140 kVp) by low absorption in their scintillating x …
limited at higher x‐ray energies (eg, 100–140 kVp) by low absorption in their scintillating x …
Resolution at oblique incidence angles of a flat panel imager for breast tomosynthesis
JG Mainprize, AK Bloomquist, MP Kempston… - Medical …, 2006 - Wiley Online Library
Oblique incidence of x rays on an imaging detector causes blurring that reduces spatial
resolution. For simple projection imaging this effect is small and often ignored. However, for …
resolution. For simple projection imaging this effect is small and often ignored. However, for …
Rapid Monte Carlo simulation of detector DQE (f)
J Star‐Lack, M Sun, A Meyer, D Morf… - Medical …, 2014 - Wiley Online Library
Purpose: Performance optimization of indirect x‐ray detectors requires proper
characterization of both ionizing (gamma) and optical photon transport in a heterogeneous …
characterization of both ionizing (gamma) and optical photon transport in a heterogeneous …
Modeling and evaluation of a high‐resolution CMOS detector for cone‐beam CT of the extremities
Purpose Quantitative assessment of trabecular bone microarchitecture in extremity cone‐
beam CT (CBCT) would benefit from the high spatial resolution, low electronic noise, and …
beam CT (CBCT) would benefit from the high spatial resolution, low electronic noise, and …
Single-shot dual-energy x-ray imaging with a flat-panel sandwich detector for preclinical imaging
We describe a multi-layer (“sandwich”) configuration detector consisting of two x-ray imaging
flat-panel detectors for single-shot (single-kV) dual-energy imaging. An intermediate copper …
flat-panel detectors for single-shot (single-kV) dual-energy imaging. An intermediate copper …
Segmented crystalline scintillators: An initial investigation of high quantum efficiency detectors for megavoltage x‐ray imaging
A Sawant, LE Antonuk, Y El‐Mohri, Q Zhao… - Medical …, 2005 - Wiley Online Library
Electronic portal imaging devices (EPIDs) based on indirect detection, active matrix flat
panel imagers (AMFPIs) have become the technology of choice for geometric verification of …
panel imagers (AMFPIs) have become the technology of choice for geometric verification of …
An apparatus and method for directly measuring the depth‐dependent gain and spatial resolution of turbid scintillators
Purpose Turbid (powder or columnar‐structured) scintillators are widely used in indirect flat
panel detectors (I‐FPDs) for scientific, industrial, and medical radiography. Light diffusion …
panel detectors (I‐FPDs) for scientific, industrial, and medical radiography. Light diffusion …