Optimal combination of thermal resistance of insulation materials and primary fuel sources for six climate zones of Japan
J Yuan, C Farnham, K Emura - Energy and Buildings, 2017 - Elsevier
Abstract Since the East Japan great earthquake disaster in March 2011, liquefied natural
gas (LNG) to replace nuclear energy has become the most-used fuel source for energy …
gas (LNG) to replace nuclear energy has become the most-used fuel source for energy …
Energy conservation in room air conditioner unit by recovering cold energy from condensate
N Nethaji, T Mohideen, M Nethaji - International Journal of refrigeration, 2019 - Elsevier
Cooling the room with Air Conditioner condensate drips is an energy saving measure. In
tropical countries which have 70 to 80% Relative Humidity (RH) year round, the quantity of …
tropical countries which have 70 to 80% Relative Humidity (RH) year round, the quantity of …
Parametric study of condensation at heating, ventilation, and air-conditioning duct's external surface
The compression of insulation causes around a heating, ventilation, and air-conditioning
duct usually resulted in dew formation around the outer surfaces because of low …
duct usually resulted in dew formation around the outer surfaces because of low …
Determining optimum insulation thickness by thermoeconomic analysis for a pipeline system in a subway central cooling system
H Yin, H Guo, Z Lin, W Xiao, Z Duan - Applied Thermal Engineering, 2018 - Elsevier
Thermoeconomic analysis combines exergy and economic analysis to evaluate and
improve the performance of energy systems. This study utilized exergetic production cost …
improve the performance of energy systems. This study utilized exergetic production cost …
[PDF][PDF] Optimum insulation thickness for HVAC duct: an energy conservation measure
MH Khan, MA Abro, J Soomro, Y Aftab… - Engineering Science …, 2018 - researchgate.net
Building Energy consumption is responsible for major share of global energy demand (40%)
which is mainly consumed to maintain building space cooling and heating requirement …
which is mainly consumed to maintain building space cooling and heating requirement …
Effet des conditions périodiques sur la précision des résultats numériques des problèmes de transfert thermique instationnaire: Cas de l'étude d'une isolation …
H NECIB - dspace.univ-ouargla.dz
Les effets des conditions périodiques et initiales sur la précision du calcul, par simulation
numérique, de l'épaisseur optimale d'isolation des murs de bâtiments ont été étudiés. Dans …
numérique, de l'épaisseur optimale d'isolation des murs de bâtiments ont été étudiés. Dans …