[HTML][HTML] Low voltage ride through capability for resilient electrical distribution system integrated with renewable energy resources

M Yadav, N Pal, DK Saini - Energy Reports, 2023 - Elsevier
It is evident that renewable energy sources (RES), will soon be considered as primary
energy source in electrical networks. However, the increased penetration of RES along with …

Mitigation of power oscillations for energy harvesting capability improvement of grid-connected renewable energy systems

Ö Çelik, M Büyük, A Tan - Electric Power Systems Research, 2022 - Elsevier
The increasing penetration of renewable energy sources in the power system raises several
challenges from the power quality and output power fluctuations point of view. However, the …

A short review of grid voltage sags and current control techniques of voltage source inverters in distributed power generation systems

M Hamdi, M Hamouda - Renewable Energy Production and Distribution, 2022 - Elsevier
Voltage sags are considered among the most severe grid faults giving rise to overcurrent
problems and uncontrolled power oscillations. Distributed power generation systems which …

On biased harmonic signal estimation: Application to electric power grid monitoring

H Ahmed, R Ushirobira, D Efimov - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Parametric estimation of a biased harmonic signal is a significant technical challenge for
many engineering applications. Such a problem is particularly important for electric utility …

Synchronverters with Fault Ride-Through Capabilities for Reliable Microgrid Protection during Balanced and Unbalanced Faults

S Pola, M Azzouz, M Mirhassani - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
Synchronverters are inverters that provide damping and inertia, similar to synchronous
generators. Like traditional inverters, synchronverters are adaptable to the microgrid's …

Fault ride through enhancement of large‐scale solar plants using distributed converters

SMH Mousavi, T Ghanbari, E Farjah… - IET Renewable …, 2024 - Wiley Online Library
The grid‐connected photovoltaic plants (GCPVPs) encounter various types of anomalies
during fault occurrence in the main grid. During a fault occurrence on the grid side, the …

[HTML][HTML] Robust estimation of fundamental frequency positive-sequence component for grid-integration applications in energy systems

H Ahmed, R Ushirobira, D Efimov - Energy Reports, 2022 - Elsevier
This article studies the problem of fundamental frequency positive-sequence component
separation in unbalanced three-phase systems for grid-integration applications. We propose …

Arbitrarily fast delayed signal cancellation PLL for grid‐integration of renewable energy sources

H Ahmed, R Ushirobira, D Efimov - IET Renewable Power …, 2022 - Wiley Online Library
Integrating renewable energy sources into an unbalanced distribution network requires fast
and accurate extraction of fundamental frequency positive‐and negative‐sequence …

Improved Low Voltage Ride-through Capability of PV Connected to the Unbalanced Main Grid

A Azamian, B Rezaeealam, T Ghanbari… - Journal of Solar Energy …, 2023 - jser.ut.ac.ir
Because of the commitment between the large-scale photovoltaic power plants and the main
grid to cope with different low voltage conditions in the grid, Low Voltage Ride Through …

Sequence extraction-based low voltage ride-through control of grid-connected renewable energy systems

F Benyamina, H Ahmed, A Benrabah… - … and Sustainable Energy …, 2023 - Elsevier
Various faults can cause voltage sag in the power grid at different voltage levels across the
network. Balanced or unbalanced voltage sags lead to grid instability by tripping off a large …