[PDF][PDF] Optimal location and sizing of DG and D-STATCOM in distribution networks
SR Salkuti - Indonesian Journal of Electrical Engineering …, 2019 - pdfs.semanticscholar.org
The main aim of this paper is to determine optimal locations and sizing of Distributed
Generations (DGs) and Distribution STATic COMpensator (D-STATCOM) in the distribution …
Generations (DGs) and Distribution STATic COMpensator (D-STATCOM) in the distribution …
New strategy to enhance AC grid performance with SVC device in an optimal location
Voltage and reactive power become one of the most critical aspects to monitor and sustain
at an appropriate level in vast alternative current networks to ensure good functionality, load …
at an appropriate level in vast alternative current networks to ensure good functionality, load …
Rotor Angle Stability Analysis with Coordinated Control of FACTS Devices Using Particle Swarm Optimization
M Pandya - 2024 IEEE 12th International Conference on Smart …, 2024 - ieeexplore.ieee.org
Electrical load demand on existing transmission lines is growing day by day throughout the
world as the economy grows. This increase in electrical energy expenditure, as well as the …
world as the economy grows. This increase in electrical energy expenditure, as well as the …
[PDF][PDF] Transient stability enhancement of statcom integration in power grid
IA Ethmane, AK Mahmoud, M Maaroufi… - Indonesian Journal of …, 2019 - academia.edu
To solve load growth of a hybrid existing electrical system, we at first build generation
stations (wind, solar or thermical). And secondly in 2025 year, when the system is so …
stations (wind, solar or thermical). And secondly in 2025 year, when the system is so …
[PDF][PDF] Improving voltage collapse point under transmission line outage by optimal placement and sizing of SVC using genetic algorithm
In many power systems, voltage instability can increase the risk of voltage collapse and, as a
result, turn the power system toward a blackout. Therefore, increasing the voltage collapse …
result, turn the power system toward a blackout. Therefore, increasing the voltage collapse …
[PDF][PDF] Transient stability assessment by coordinated control of SVC and TCSC with particle swarm optimization
M Pandya, JG Jamnani - Int. J. Eng. Adv. Technol, 2019 - researchgate.net
This paper aims on improving the stability of a 9 bus power system under fault condition
using coordination of FACTS device. Flexible AC transmission system (FACTS) can be …
using coordination of FACTS device. Flexible AC transmission system (FACTS) can be …
Improve monitoring system of interconnected oscillation power system based on PMU technology
M Tsebia, H Betarzi - 2020 International Conference on …, 2020 - ieeexplore.ieee.org
Interconnected power systems have a very important role between several countries, the
conditions of interconnections are strict in order to ensure the good quality of energy …
conditions of interconnections are strict in order to ensure the good quality of energy …
Voltage Stability enhancement by Coordinated design of FACTS devices by Particle Swarm Optimization algorithm
JG Jamnani, MC Pandya - 2020 IEEE REGION 10 …, 2020 - ieeexplore.ieee.org
The grow of electrical energy utilization and day by day increment of nonlinear loads in
power system forced for high electrical power and better stability. Flexible AC Transmission …
power system forced for high electrical power and better stability. Flexible AC Transmission …