Flow diversion for intracranial aneurysm treatment: trials involving flow diverters and long-term outcomes
Flow diverters (FDs) have changed the management of brain aneurysms; not only for
complex aneurysms (giant, fusiform and blister) refractory to conventional therapies, but also …
complex aneurysms (giant, fusiform and blister) refractory to conventional therapies, but also …
Long-term clinical and angiographic outcomes following pipeline embolization device treatment of complex internal carotid artery aneurysms: five-year results of the …
T Becske, W Brinjikji, MB Potts, DF Kallmes… - …, 2017 - journals.lww.com
BACKGROUND: Early and mid-term safety and efficacy of aneurysm treatment with the
Pipeline Embolization Device (PED) has been well demonstrated in prior studies …
Pipeline Embolization Device (PED) has been well demonstrated in prior studies …
Antiplatelet therapy and the risk of ischemic and hemorrhagic complications associated with Pipeline embolization of cerebral aneurysms: a systematic review and …
H Saber, RY Kherallah, MO Hadied… - Journal of …, 2019 - jnis.bmj.com
Background Pipeline embolization devices (PEDs) are increasingly used in the treatment of
cerebral aneurysms. Yet, major ischemic or hemorrhagic complications after PED treatment …
cerebral aneurysms. Yet, major ischemic or hemorrhagic complications after PED treatment …
[HTML][HTML] The fate of side branches covered by flow diverters–results from 140 patients
P Bhogal, O Ganslandt, H Bäzner, H Henkes… - World neurosurgery, 2017 - Elsevier
Background Flow diverter stents (FDS) are a recognized treatment option for intracranial
aneurysms. There remain ongoing concerns regarding the safety of FDS, especially …
aneurysms. There remain ongoing concerns regarding the safety of FDS, especially …
Learning from failure: persistence of aneurysms following pipeline embolization
M Shapiro, T Becske, PK Nelson - Journal of Neurosurgery, 2017 - thejns.org
OBJECTIVE A detailed analysis was performed of anterior circulation aneurysms treated
with a Pipeline Embolization Device (PED) that did not progress to complete occlusion by 1 …
with a Pipeline Embolization Device (PED) that did not progress to complete occlusion by 1 …
Stent-assisted coiling of cerebral aneurysms using the Y-stenting technique: a systematic review and meta-analysis
MF Granja, GM Cortez, P Aguilar-Salinas… - Journal of …, 2019 - jnis.bmj.com
Background Bifurcation aneurysms can be treated with stent-assisted coiling using two
stents in a Y-configuration. We aim to investigate the angiographic and clinical outcomes of …
stents in a Y-configuration. We aim to investigate the angiographic and clinical outcomes of …
Patency of the posterior communicating artery following treatment with the Pipeline Embolization Device
OBJECTIVE The Pipeline Embolization Device (PED) has become an effective treatment
strategy for some cerebral aneurysms. Concerns regarding the patency of branch arteries …
strategy for some cerebral aneurysms. Concerns regarding the patency of branch arteries …
Occlusion rate and visual complications with flow-diverter stent placed across the ophthalmic artery's origin for carotid-ophthalmic aneurysms: a meta-analysis
R Touzé, B Gravellier, C Rolla-Bigliani, V Touitou… - …, 2020 - journals.lww.com
BACKGROUND Flow-diverter stents (FDSs) have recently gained acceptance for the
treatment of intracranial aneurysms, especially for carotid-ophthalmic aneurysms (COAs) …
treatment of intracranial aneurysms, especially for carotid-ophthalmic aneurysms (COAs) …
Endovascular treatment of ophthalmic artery aneurysms: ophthalmic artery patency following flow diversion versus coil embolization
CR Durst, RM Starke, D Clopton, HR Hixson… - Journal of …, 2016 - jnis.bmj.com
Background and purpose The Pipeline Embolization Device (PED) has been shown to
effectively treat complex internal carotid artery aneurysms while maintaining patency of …
effectively treat complex internal carotid artery aneurysms while maintaining patency of …
Comparison of pipeline embolization device sizing based on conventional 2D measurements and virtual simulation using the Sim&Size software: an agreement study
JM Ospel, G Gascou, V Costalat… - American Journal …, 2019 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: The Sim&Size software simulates case-specific
intraluminal Pipeline Embolization Device behavior, wall apposition, and device length in …
intraluminal Pipeline Embolization Device behavior, wall apposition, and device length in …