Coagulation tests predict bleeding after cardiopulmonary bypass

GA Nuttall, WC Oliver, MH Ereth, PJ Santrach - Journal of cardiothoracic …, 1997 - Elsevier
Objective: To determine the accuracy of coagulation profile laboratory tests,
thromboelastography, and Sonoclot (SCT) values for predicting microvascular bleeding after …

Determination of normal versus abnormal activated partial thromboplastin time and prothrombin time after cardiopulmonary bypass

GA Nuttall, WC Oliver, FM Beynen, PJ Santrach… - Journal of cardiothoracic …, 1995 - Elsevier
OBJECTIVE:: The study's objective was to determine the prothrombin time (PT) and
activated partial thromboplastin time (aPTT) values that differentiated normal from …

Activated coagulation time vs. intrinsically activated modified rotational thromboelastometry in assessment of hemostatic disturbances and blood loss after protamine …

M Petricevic, B Biocina, D Milicic, L Svetina… - Journal of …, 2014 - Springer
Background Excessive bleeding after cardiopulmonary bypass (CPB) is risk factor for
adverse outcomes after elective cardiac surgery (ECS). Although many different point-of …

Intraoperative measurement of activated partial thromboplastin time and prothrombin time by a portable laser photometer in patients following cardiopulmonary …

GA Nuttall, WC Oliver Jr, FM Beynen, JJ Dull… - Journal of cardiothoracic …, 1993 - Elsevier
Intraoperative capabilities to rapidly assess coagulation status following cardiopulmonary
bypass (CPB) may be of benefit in providing optimal hemostasis and transfusion …

Comparison of Anti–Factor Xa Heparin Activity and Activated Partial Thromboplastin Time in 2,773 Plasma Samples From Unfractionated Heparin–Treated Patients

TK Rosborough - American journal of clinical pathology, 1997 - academic.oup.com
This study was conducted to evaluate two methods of determining the “therapeutic range” of
the activated partial thromboplastin time (APTT) during unfractionated heparin treatment …

Automated instrumentation and the laboratory diagnosis of bleeding and thrombotic disorders

J Walenga, J Fareed, EW Bermes - Seminars in Thrombosis …, 1983 - thieme-connect.com
Due to the contributions of various disciplines that have elucidated the molecular
mechanisms involved in the physiologic regulation and pathologic alterations of the …

Heparin monitoring and neutralization during cardiopulmonary bypass using a rapid plasma separator and a fluorometric assay

J Umlas, G Gauvin, R Taff - The Annals of thoracic surgery, 1984 - Elsevier
Avoidance of over-or underheparinization during cardiopulmonary bypass (CPB) is crucial
in preventing bleeding or clotting. Currently no completely satisfactory method is available …

[图书][B] A non-clotting and non-instrumental method for sensing heparin and monitoring of extracorporeal anticoagulation

W Chen - 1991 - search.proquest.com
A non-clotting and non-instrumentally based heparin assay was developed. This was
achieved by studying the immobilization of protamine (a heparin antidote) on a porous filter …

[PDF][PDF] Mate Petricevic1, Bojan Biocina1, Davor Milicic2, Lucija Svetina1, Marko Boban3, Ante Lekić1, Sanja Konosic4

M Milosevic, H Gasparovic - 2014 - cardiothoracicsurgery.biomedcentral …
Background: Excessive bleeding after cardiopulmonary bypass (CPB) is risk factor for
adverse outcomes after elective cardiac surgery (ECS). Although many different point-of …

Activated Clotting Time for Heparin Dosage Monitoring in Continuous Arteriovenous Hemofiltration

K Koorejian, RH Bartlett, J London - … A Kidney Replacement Therapy for the …, 1985 - Springer
The main purpose of heparinization in continuous arteriovenous hemofiltration (CAVH) is to
prevent the hemofilter from clotting without having to systemically anticoagulate the patient …