Dynamic behavior of R/C elevated tanks with soil–structure interaction

SC Dutta, S Dutta, R Roy - Engineering Structures, 2009 - Elsevier
A critical review of past earthquakes reveals damage/failure of important lifeline facilities like
elevated water tanks in recurrence, leading to serious hazards even after the event. In the …

Effect of foundation embedment on seismic behavior of elevated tanks considering fluid–structure-soil interaction

R Livaoglu, A Dogangun - Soil Dynamics and Earthquake Engineering, 2007 - Elsevier
This paper investigates the effects of foundation embedment on the seismic behavior of fluid-
elevated tank-foundation–soil system with a structural frame supporting the fluid containing …

Shake table investigation of nonlinear soil–structure–fluid interaction of a thin-walled storage tank under earthquake load

D Hernandez-Hernandez, T Larkin, N Chouw - Thin-Walled Structures, 2021 - Elsevier
This research experimentally addresses the seismic response of a cylindrical liquid storage
tank in terms of six factors, ie, acceleration, displacement, hoop and axial stresses in the …

Seismic response of column supported tanks considering uplift effect and soil‐structure interaction

J Liu, M Zhao, J Zhou - Earthquake Engineering & Structural …, 2023 - Wiley Online Library
In this paper, the seismic responses of column supported tanks under horizontal earthquake
are obtained by finite element method. Two types of structures are discussed including the …

Effects of soil-structure interaction on seismic response of fixed base and base isolated liquid storage tanks

H Kumar, SK Saha - Journal of Earthquake Engineering, 2022 - Taylor & Francis
ABSTRACT A detailed numerical framework for seismic analysis of liquid storage tanks
considering soil-structure interaction (SSI) is presented. Lumped mass model for the tank …

Seismic performance of base-isolated elevated liquid storage tanks considering soil–structure interaction

H Kumar, SK Saha - Practice Periodical on Structural Design and …, 2021 - ascelibrary.org
Seismic performance of elevated liquid storage tanks, considering soil–structure interaction
(SSI), is investigated. The effects of considering SSI on the peak seismic responses, as well …

Performance-based assessment of response reduction factor of RC-elevated water tank considering soil flexibility: a case study

KN Patel, JA Amin - International Journal of Advanced Structural …, 2018 - Springer
The seismic design codes/standards of most countries include the nonlinear response of a
structure implicitly through a response reduction/modification factor (R). It is the factor by …

Seismic assessment of different vertical bracing systems in staging of elevated liquid retaining tank

AK Pathak, A Mishra - Materials Today: Proceedings, 2023 - Elsevier
The study of earthquakes indicates that earthquakes have a significant impact on the grid
system, as well as significant catastrophic effects on human life, buildings, bridges and other …

Evaluation of response modification factor (R) of elevated concrete tanks

M Masoudi, S Eshghi, M Ghafory-Ashtiany - Engineering Structures, 2012 - Elsevier
This paper discusses the failure mechanism of elevated concrete tanks with shaft and frame
staging (supporting system) along with seismic behavior of these construction types. In order …

A review of fluid-structure-soil interaction in elevated water tanks

JB Chouhan, AM Gharad - International Journal of Structural …, 2024 - inderscienceonline.com
Water, a vital resource for sustaining life, requires proper storage. Elevated water tanks are
constructed to serve this purpose. These tanks must operate reliably, even during and after …