[HTML][HTML] How to measure intraocular pressure: an updated review of various tonometers

P Brusini, ML Salvetat, M Zeppieri - Journal of clinical medicine, 2021 - mdpi.com
Intraocular pressure (IOP) is an important measurement that needs to be taken during
ophthalmic examinations, especially in ocular hypertension subjects, glaucoma patients and …

Measuring intraocular pressure

KC Okafor, JD Brandt - Current opinion in ophthalmology, 2015 - journals.lww.com
There is no perfect tonometer, and clinicians must choose which to use in their daily
practice, balancing accuracy, precision, convenience, and cost. Clinicians should recognize …

Evaluation of a novel Scheimpflug-based non-contact tonometer in healthy subjects and patients with ocular hypertension and glaucoma

L Reznicek, D Muth, A Kampik, AS Neubauer… - British Journal of …, 2013 - bjo.bmj.com
Background To evaluate the agreement of intraocular pressure (IOP) and central corneal
thickness (CCT) measurements obtained with the non-contact tonometer Corvis …

The Icare HOME (TA022) study: performance of an intraocular pressure measuring device for self-tonometry by glaucoma patients

LI Mudie, S LaBarre, V Varadaraj, S Karakus, J Onnela… - Ophthalmology, 2016 - Elsevier
Purpose To evaluate the Icare HOME (TA022) device (Icare Oy, Vanda, Finland) for use by
glaucoma patients for self-tonometry. Design Prospective performance evaluation of a …

[HTML][HTML] Ophthalmology going greener: a narrative review

YL Wong, M Noor, KL James, TM Aslam - Ophthalmology and therapy, 2021 - Springer
The combined effects of fossil fuel combustion, mass agricultural production and
deforestation, industrialisation and the evolution of modern transport systems have resulted …

Evaluation of a new rebound self-tonometer, Icare HOME: comparison with Goldmann applanation tonometer

D Takagi, A Sawada, T Yamamoto - Journal of Glaucoma, 2017 - journals.lww.com
Purpose: To compare measurements from an Icare HOME rebound self-tonometer
compared with those from a Goldmann applanation tonometer (GAT). Materials and …

C ambridge community O ptometry G laucoma S cheme

J Keenan, H Shahid, RR Bourne… - Clinical & …, 2015 - Wiley Online Library
Background With a higher life expectancy, there is an increased demand for hospital
glaucoma services in the United Kingdom. Design The Cambridge community Optometry …

The effectiveness of schemes that refine referrals between primary and secondary care—the UK experience with glaucoma referrals: the Health Innovation & …

G Ratnarajan, W Newsom, SA Vernon, C Fenerty… - BMJ open, 2013 - bmjopen.bmj.com
Objectives A comparison of glaucoma referral refinement schemes (GRRS) in the UK during
a time period of considerable change in national policy and guidance. Design Retrospective …

Comparability of Icare pro rebound tonometer with Goldmann applanation and noncontact tonometer in a wide range of intraocular pressure and central corneal …

N Tamçelik, E Atalay, E Cicik, A Özkök - Ophthalmic Research, 2015 - karger.com
Purpose: To evaluate the agreement between the reading values of the Goldmann
applanation tonometer (GAT), Icare Pro rebound tonometer (IRT) and noncontact tonometer …

[HTML][HTML] Influence of scleral lens on intraocular pressure

AP Aitsebaomo, J Wong-Powell, W Miller… - Journal of Contact lens …, 2019 - jclrs.org
Purpose Since Scleral Lenses (SL) rest entirely on the sclera and may affect underlying
anatomical structures that may influence aqueous humor flow, it is important to determine …