[HTML][HTML] Mitigation of power system oscillations in weak grids with battery energy storage systems: A real-world case study
Sub-synchronous oscillations are becoming commonplace in weak areas of power systems
with high levels of renewable generation, affecting their operation. Moreover, there is a lack …
with high levels of renewable generation, affecting their operation. Moreover, there is a lack …
PLL based sub-/super-synchronous resonance damping controller for D-PMSG wind farm integrated power systems
Existing sub-/super-synchronous (SSO) suppression methods for the direct-drive permanent
magnet synchronous generators (D-PMSG) integrated power systems are mainly achieved …
magnet synchronous generators (D-PMSG) integrated power systems are mainly achieved …
Large-signal stability analysis of inverter-based AC microgrids: A critical and analytical review
With the ever-increasing development of microgrids to improve power supply reliability and
resilience, large-signal stability analysis of microgrids is needed to provide accurate insights …
resilience, large-signal stability analysis of microgrids is needed to provide accurate insights …
RHP Poles Trajectory Study for DQ Impedance-based Stability Monitoring using a Power-Hardware-in-the-Loop Testbed
Using impedance-based stability analysis for ac grids has become an extensively accepted
method. Online impedance-based stability monitoring, which requires assessing system …
method. Online impedance-based stability monitoring, which requires assessing system …
Triple current control of four-wire inverter-interfaced DGs for correct fault type identification
W Medhat, MA Azzouz - IEEE Transactions on Smart Grid, 2022 - ieeexplore.ieee.org
Inverter-interfaced distributed generators (IIDGs) have fault current signatures that could
jeopardize protective relaying. This paper unveils the failure of phase selection methods …
jeopardize protective relaying. This paper unveils the failure of phase selection methods …
[HTML][HTML] Impedance modelling and stability improvement for high frequency isolated power conversion system based on dual active bridge
Two-stage high frequency isolated power conversion system integrated with dual active
bridges is a preferable choice to serve as a bidirectional interface between the battery packs …
bridges is a preferable choice to serve as a bidirectional interface between the battery packs …
Finite-Difference-Impedance Method for Time-Delay Systems
J Segundo-Ramírez, J Hernández-Ramírez… - IEEE …, 2022 - ieeexplore.ieee.org
The stability issues assessment by the impedance-based method demands the computation
of accurate small-signal models. However, obtaining impedance models can be a time …
of accurate small-signal models. However, obtaining impedance models can be a time …
An Additional Resonance Damping Control for Grey-Box D-PMSG Wind Farm Integrated Weak Grid
Considerable efforts have been made to address the resonance issue of the Direct-drive
Permanent Magnet Synchronous Generator (D-PMSG) wind farm integrated power systems …
Permanent Magnet Synchronous Generator (D-PMSG) wind farm integrated power systems …
[HTML][HTML] Cooperative control of battery energy storage systems with detail-balanced digraph: A prespecified-time observer-based approach
Distributed control of (BESSs) battery energy storage systems plays an significant role in the
practical operation of microgrid. This paper studies the power tracking and (SoC) state-of …
practical operation of microgrid. This paper studies the power tracking and (SoC) state-of …
A data‐driven identification method for impedance stability analysis of inverter‐based resources
Obtaining inverter controller information may be a premise for seeking its dynamic
behaviour. But accurate knowledge of such information would be unrealistic for real …