[HTML][HTML] Mitigation of power system oscillations in weak grids with battery energy storage systems: A real-world case study

F Arraño-Vargas, S Jiang, B Bennett, G Konstantinou - Energy, 2023 - Elsevier
Sub-synchronous oscillations are becoming commonplace in weak areas of power systems
with high levels of renewable generation, affecting their operation. Moreover, there is a lack …

PLL based sub-/super-synchronous resonance damping controller for D-PMSG wind farm integrated power systems

S Yang, R Shen, J Shu, T Zhang, Y Li… - IEEE Transactions …, 2022 - ieeexplore.ieee.org
Existing sub-/super-synchronous (SSO) suppression methods for the direct-drive permanent
magnet synchronous generators (D-PMSG) integrated power systems are mainly achieved …

Large-signal stability analysis of inverter-based AC microgrids: A critical and analytical review

H Hosseinpour, M MansourLakouraj, M Benidris… - IEEE …, 2023 - ieeexplore.ieee.org
With the ever-increasing development of microgrids to improve power supply reliability and
resilience, large-signal stability analysis of microgrids is needed to provide accurate insights …

RHP Poles Trajectory Study for DQ Impedance-based Stability Monitoring using a Power-Hardware-in-the-Loop Testbed

Q Lin, B Wen, R Burgos - … of Emerging and Selected Topics in …, 2023 - ieeexplore.ieee.org
Using impedance-based stability analysis for ac grids has become an extensively accepted
method. Online impedance-based stability monitoring, which requires assessing system …

Triple current control of four-wire inverter-interfaced DGs for correct fault type identification

W Medhat, MA Azzouz - IEEE Transactions on Smart Grid, 2022 - ieeexplore.ieee.org
Inverter-interfaced distributed generators (IIDGs) have fault current signatures that could
jeopardize protective relaying. This paper unveils the failure of phase selection methods …

[HTML][HTML] Impedance modelling and stability improvement for high frequency isolated power conversion system based on dual active bridge

N Gao, L Wang, W Wu, L Zhu, S Sang, R Li - Journal of Energy Storage, 2024 - Elsevier
Two-stage high frequency isolated power conversion system integrated with dual active
bridges is a preferable choice to serve as a bidirectional interface between the battery packs …

Finite-Difference-Impedance Method for Time-Delay Systems

J Segundo-Ramírez, J Hernández-Ramírez… - IEEE …, 2022 - ieeexplore.ieee.org
The stability issues assessment by the impedance-based method demands the computation
of accurate small-signal models. However, obtaining impedance models can be a time …

An Additional Resonance Damping Control for Grey-Box D-PMSG Wind Farm Integrated Weak Grid

T Zhang, S Yang, Z Hao, H Ma… - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
Considerable efforts have been made to address the resonance issue of the Direct-drive
Permanent Magnet Synchronous Generator (D-PMSG) wind farm integrated power systems …

[HTML][HTML] Cooperative control of battery energy storage systems with detail-balanced digraph: A prespecified-time observer-based approach

W Yang, SM Liang, YW Wang, XK Liu - Energy Reports, 2024 - Elsevier
Distributed control of (BESSs) battery energy storage systems plays an significant role in the
practical operation of microgrid. This paper studies the power tracking and (SoC) state-of …

A data‐driven identification method for impedance stability analysis of inverter‐based resources

H Wang, P Sun, J Sahebkar Farkhani, Z Chen - IET Smart Grid, 2024 - Wiley Online Library
Obtaining inverter controller information may be a premise for seeking its dynamic
behaviour. But accurate knowledge of such information would be unrealistic for real …