A survey of medical image registration

JBA Maintz, MA Viergever - Medical image analysis, 1998 - Elsevier
The purpose of this paper is to present a survey of recent (published in 1993 or later)
publications concerning medical image registration techniques. These publications will be …

Medical image registration

DLG Hill, PG Batchelor, M Holden… - Physics in medicine & …, 2001 - iopscience.iop.org
Radiological images are increasingly being used in healthcare and medical research. There
is, consequently, widespread interest in accurately relating information in the different …

OASIS-3: longitudinal neuroimaging, clinical, and cognitive dataset for normal aging and Alzheimer disease

PJ LaMontagne, TLS Benzinger, JC Morris, S Keefe… - MedRxiv, 2019 - medrxiv.org
ABSTRACT OASIS-3 is a compilation of MRI and PET imaging and related clinical data for
1098 participants who were collected across several ongoing studies in the Washington …

Improved optimization for the robust and accurate linear registration and motion correction of brain images

M Jenkinson, P Bannister, M Brady, S Smith - Neuroimage, 2002 - Elsevier
Linear registration and motion correction are important components of structural and
functional brain image analysis. Most modern methods optimize some intensity-based cost …

A global optimisation method for robust affine registration of brain images

M Jenkinson, S Smith - Medical image analysis, 2001 - Elsevier
Registration is an important component of medical image analysis and for analysing large
amounts of data it is desirable to have fully automatic registration methods. Many different …

A pyramid approach to subpixel registration based on intensity

P Thevenaz, UE Ruttimann… - IEEE transactions on …, 1998 - ieeexplore.ieee.org
We present an automatic subpixel registration algorithm that minimizes the mean square
intensity difference between a reference and a test data set, which can be either images (two …

Medial prefrontal cortex and self-referential mental activity: relation to a default mode of brain function

DA Gusnard, E Akbudak… - Proceedings of the …, 2001 - National Acad Sciences
Medial prefrontal cortex (MPFC) is among those brain regions having the highest baseline
metabolic activity at rest and one that exhibits decreases from this baseline across a wide …

Accurate, robust, and automated longitudinal and cross-sectional brain change analysis

SM Smith, Y Zhang, M Jenkinson, J Chen… - Neuroimage, 2002 - Elsevier
Quantitative measurement of brain size, shape, and temporal change (for example, in order
to estimate atrophy) is increasingly important in biomedical image analysis applications …

Extension of phase correlation to subpixel registration

H Foroosh, JB Zerubia… - IEEE transactions on image …, 2002 - ieeexplore.ieee.org
In this paper, we have derived analytic expressions for the phase correlation of
downsampled images. We have shown that for downsampled images the signal power in …

Modeling geometric deformations in EPI time series

JLR Andersson, C Hutton, J Ashburner, R Turner… - Neuroimage, 2001 - Elsevier
Even after realignment there is residual movement-related variance present in fMRI time-
series, causing loss of sensitivity and, potentially, also specificity. One cause is the …