Design strategies of viscous dampers for seismic protection of building structures: a review

D De Domenico, G Ricciardi, I Takewaki - Soil dynamics and earthquake …, 2019 - Elsevier
Fluid viscous dampers (FVDs) are well-established supplemental energy dissipation
devices that have been widely used for earthquake protection of structures. Optimal design …

Current trends in fluid viscous dampers with semi-active and adaptive behavior

L Zoccolini, E Bruschi, S Cattaneo, V Quaglini - Applied Sciences, 2023 - mdpi.com
Fluid viscous dampers (FVDs) have shown their efficiency as energy-dissipating systems,
reducing the effects induced on structures by dynamic loading conditions like earthquakes …

Multi-level performance-based design optimisation of steel frames with nonlinear viscous dampers

D De Domenico, I Hajirasouliha - Bulletin of Earthquake Engineering, 2021 - Springer
This paper presents a practical multi-level performance-based optimisation method of
nonlinear viscous dampers (NVDs) for seismic retrofit of existing substandard steel frames. A …

Influence of viscous dampers ultimate capacity on the seismic reliability of building structures

F Scozzese, L Gioiella, A Dall'Asta, L Ragni, E Tubaldi - Structural Safety, 2021 - Elsevier
Anti-seismic devices should be designed with proper safety margins against their failure,
because the reliability of the structural system where they are installed is strongly influenced …

Experimental study on the dynamic performance of a winding rope fluid viscous damper

W Zhang, C Zhang, L Su, Y Zheng, X Du - Engineering Structures, 2023 - Elsevier
This study proposed a winding rope fluid viscous damper (WRFVD) using the winding ropes
to amplify the damping force of a fluid viscous damper. To investigate the dynamic …

A novel brace-damper system for seismic response suppression of high-rise steel frame structures

X Liu, Y Ding, H Zhang, H Zhao, A Li - Journal of Building Engineering, 2023 - Elsevier
Chevron-brace-damper systems (CBDS) have been widely used in frame structures. To
improve the performance of CBDS, a hybrid of the chevron and scissor-jack brace-damper …

Parametric study and prediction models of the seismic response of single-degree-of-freedom structural systems equipped with Maxwell material fluid viscous dampers

B Chalarca, A Filiatrault, D Perrone - Structures, 2022 - Elsevier
The addition of supplemental damping through fluid viscous dampers has been widely
implemented as a seismic protection system for diverse typologies of structures. Typically …

Performance‐based seismic retrofitting of frame structures using negative stiffness devices and fluid viscous dampers via optimization

O Idels, O Lavan - Earthquake Engineering & Structural …, 2021 - Wiley Online Library
In this paper, an optimization approach for the seismic retrofitting of inelastic moment
resisting frames (MRFs) equipped with nonlinear fluid viscous dampers (FVDs) and negative …

Simultaneous layout and size optimization of nonlinear viscous dampers for frame buildings under stochastic seismic excitation

L Li, Y Liang, G Chen, D Yang - Engineering Structures, 2022 - Elsevier
Viscous dampers, as effective energy-dissipation devices, have been widely used for
seismic mitigation of building structures. Due to the intrinsic uncertainties of structural …

Optimal design and distribution of viscous dampers for shear building structures under seismic excitations

H Cetin, E Aydin, B Ozturk - Frontiers in Built Environment, 2019 - frontiersin.org
Viscous dampers (VDs) are effective and widely used passive devices for the protection of
civil structures, provided that appropriate design is carried out. For this purpose, optimal …