Development and applications of STIM-and PIXE-tomography: A review

C Michelet, P Barberet, P Moretto, H Seznec - Nuclear Instruments and …, 2015 - Elsevier
In combination with nuclear microprobes, STIM and PIXE tomography offer non-destructive
quantitative three-dimensional characterization of microscopic samples. STIM tomography …

Accuracy of three-dimensional proton imaging of an inertial confinement fusion target assessed by Geant4 simulation

Z Li, S Incerti, D Beasley, H Shen, S Wang… - Nuclear Instruments and …, 2023 - Elsevier
The Geant4 toolkit was used to perform benchmark Monte Carlo simulations of proton micro-
tomography imaging. A phantom of an inertial confinement fusion (ICF) target was designed …

Proton‐induced x‐ray fluorescence CT imaging

M Bazalova‐Carter, M Ahmad, T Matsuura… - Medical …, 2015 - Wiley Online Library
Purpose: To demonstrate the feasibility of proton‐induced x‐ray fluorescence CT (pXFCT)
imaging of gold in a small animal sized object by means of experiments and Monte Carlo …

A dual-PIXE tomography setup for reconstruction of Germanium in ICF target

N Guo, HY Lu, Q Wang, J Meng, DZ Gao… - Nuclear Instruments and …, 2017 - Elsevier
Abstract Inertial Confinement Fusion (ICF) is one type of fusion energy research which could
initiate nuclear fusion reactions through heating and compressing thermonuclear fuel …

A comparison of quantitative reconstruction techniques for PIXE-tomography analysis applied to biological samples

DG Beasley, LC Alves, P Barberet, S Bourret… - Nuclear Instruments and …, 2014 - Elsevier
The tomographic reconstruction of biological specimens requires robust algorithms, able to
deal with low density contrast and low element concentrations. At the IST/ITN microprobe …

Application of silicon drift detector in PIXE tomography system of Fudan University

S Wang, T Yu, J Li, H Xue, X Liu, W Zhang… - Nuclear Instruments and …, 2022 - Elsevier
Abstract In the Nuclear Microprobe Laboratory of Fudan University, particle induced X-ray
emission (PIXE) has invariably used the Si (Li) detector. Although it is a widely used X-ray …

A Geant4 simulation of X-ray emission for three-dimensional proton imaging of microscopic samples

C Michelet, Z Li, H Jalenques, S Incerti, P Barberet… - Physica Medica, 2022 - Elsevier
Purpose Proton computed microtomography is a technique that reveals the inner content of
microscopic samples. The density distribution of the material (in g· cm− 3) is obtained from …

Reconstruction of Ge spatial distribution in ICF target using PIXE-T

HY Lu, XD He, J Meng, N Guo, CC Rong… - Fusion Engineering and …, 2016 - Elsevier
Inertial confinement fusion (ICF) target is a microsphere with diameter at millimeter scale
and shell thickness at micrometer scale. Ge-doped glow discharge polymer (GDP) is an …

An implementation of the NiftyRec medical imaging library for PIXE-tomography reconstruction

C Michelet, P Barberet, P Desbarats… - Nuclear Instruments and …, 2017 - Elsevier
A new development of the TomoRebuild software package is presented, including “thick
sample” correction for non linear X-ray production (NLXP) and X-ray absorption (XA). As in …

Implementation of the EPICS2017 electron-photon database in Geant4: developments and applications

Z Li - 2023 - theses.hal.science
Geant4 provides complementary and alternative physics models for the interaction of
photons and electrons with matter, according to the energy range. An important set of …