[HTML][HTML] Finite element analysis of the amputated lower limb: A systematic review and recommendations

AS Dickinson, JW Steer, PR Worsley - Medical engineering & physics, 2017 - Elsevier
The care and rehabilitation of individuals after lower limb amputation presents a substantial
and growing socioeconomic challenge. Clinical outcome is closely linked to successful …

Review of the socket design and interface pressure measurement for transtibial prosthesis

G Pirouzi, NA Abu Osman, A Eshraghi… - The scientific World …, 2014 - Wiley Online Library
Socket is an important part of every prosthetic limb as an interface between the residual limb
and prosthetic components. Biomechanics of socket‐residual limb interface, especially the …

Structural testing of lower-limb prosthetic sockets: a systematic review

F Gariboldi, D Pasquarelli, AG Cutti - Medical engineering & physics, 2022 - Elsevier
A lower-limb prosthetic socket is the custom-made structural element interfacing the residual
limb of a person with an amputation to their prosthetic leg comprising off-the-shelf …

[PDF][PDF] Tensile and flexural strength of ramie fiber reinforced epoxy composites for socket prosthesis application.

AP Irawan, TP Soemardi, AHS Reksoprodjo… - International Journal of …, 2011 - academia.edu
The aim of this study is to develop a socket prosthesis made from natural fibers, especially
ramie fiber reinforced epoxy composite (RE). Development of socket prosthesis with RE was …

Finite element analysis of donning procedure of a prosthetic transfemoral socket

D Lacroix, JF Ramírez Patiño - Annals of biomedical engineering, 2011 - Springer
Lower limb amputation is a severe psychological and physical event in a patient. A
prosthetic solution can be provided but should respond to a patient-specific need to …

Regional differences in pain threshold and tolerance of the transtibial residual limb: including the effects of age and interface material

WC Lee, M Zhang, AF Mak - Archives of physical medicine and …, 2005 - Elsevier
Lee WC, Zhang M, Mak AF. Regional differences in pain threshold and tolerance of the
transtibial residual limb: including the effects of age and interface material. Arch Phys Med …

Compensatory mechanism involving the hip joint of the intact limb during gait in unilateral trans-tibial amputees

C Grumillier, N Martinet, J Paysant, JM André… - Journal of …, 2008 - Elsevier
Hip dynamics in the intact limb during the beginning of stance phase in unilateral trans-tibial
amputees (TTA) was studied to evaluate its contribution to compensatory function. We …

Compensatory mechanism involving the knee joint of the intact limb during gait in unilateral below-knee amputees

C Beyaert, C Grumillier, N Martinet, J Paysant… - Gait & posture, 2008 - Elsevier
This study evaluated the asymmetry of knee kinetics during uncomfortable gait induced by
prosthesis misalignment to further demonstrate the compensatory function of the knee joint …

Finite element analysis for the evaluation of the structural behaviour, of a prosthesis for trans-tibial amputees

M Omasta, D Paloušek, T Návrat, J Rosický - Medical engineering & …, 2012 - Elsevier
The finite element analysis (FEA) has been identified as a useful tool for the stress and strain
behaviour determination in lower limb prosthetics. The residual limb and prosthetic socket …

Influence of gait cycle loads on stress distribution at the residual limb/socket interface of transfemoral amputees: a finite element analysis

SC Henao, C Orozco, J Ramírez - Scientific Reports, 2020 - nature.com
Abstract A Finite Element Analysis (FEA) was performed to evaluate the interaction between
residual limb and socket when considering the dynamic loads of the gait cycle. Fourteen …