Final design of the generic equatorial port plug structure for ITER diagnostic systems

VS Udintsev, P Maquet, E Alexandrov, N Casal… - Fusion Engineering and …, 2015 - Elsevier
Abstract The Diagnostic Generic Equatorial Port Plug (GEPP) is designed to be common to
all equatorial port-based diagnostic systems. It is designed to survive throughout the lifetime …

Integration of diagnostics on ITER

M Walsh, P Andrew, R Barnsley… - 2015 IEEE 26th …, 2015 - ieeexplore.ieee.org
Diagnostics play a very important role in the modern Tokamak where optimum performance
is essential. To achieve this, the device must be equipped with reliable and robust sensors …

Progress on final design of ITER radial X-ray camera

K Chen, L Hu, H Yu, H Cao, S Li, J Zhang… - Fusion Engineering and …, 2021 - Elsevier
The design of ITER Radial X-ray Camera (RXC) is nearly finished. The design of internal
camera was updated using gas detector modules and considering the mechanical, electrical …

[HTML][HTML] Design and FEM modeling of a fire resistant cabinet for fusion environment

R Ortwein, B Esposito, D Marocco, J Kotula… - Fusion Engineering and …, 2023 - Elsevier
Diagnostic systems in fusion environments need to satisfy stringent requirements, often
involving radiation and electromagnetic shielding as well as fire protection. A conceptual …

Design and integration of lower ports for ITER diagnostic systems

N Casal, L Bertalot, H Cheng, JM Drevon… - Fusion Engineering and …, 2015 - Elsevier
All around the ITER vacuum vessel, forty-four ports will provide access to the vacuum vessel
for remote handling operations, diagnostic systems, heating, and vacuum systems: 18 upper …

Final design of the generic upper port plug structure for ITER diagnostic systems

S Pak, R Feder, T Giacomin, J Guirao, S Iglesias… - Fusion Engineering and …, 2016 - Elsevier
The generic upper port plug (GUPP) structure in ITER is a 6 m long metal box which deploys
diagnostic components into the vacuum vessel. This structure is commonly used for all the …

Study on the effect of an equatorial diagnostic port plug on EM loads distribution in the CFETR blanket system

M Wang, Y Song, M Lei, K Lu, S Liu, K Xu… - Fusion Engineering and …, 2019 - Elsevier
Abstract The Chinese Fusion Engineering Test Reactor (CFETR) is the next step in China's
research into fusion energy. In phase I, the preliminarily design of diagnostic systems for the …

EMC Issues and Signal Integrity Analysis of Neutron Diagnostics for Nuclear Fusion Machines

A Maffucci, D Capriglione, F Pompili… - 2022 IEEE 26th …, 2022 - ieeexplore.ieee.org
This paper studies the Electromagnetic Compatibility (EMC) compliance of a diagnostic
system intended for the nuclear fusion reactor ITER. Specifically, a neutron detection chain …

Thermal assessment of ITER generic equatorial diagnostic first wall

W Song, J Guirao, A Raj, V Udintsev, X Peng… - Fusion Engineering and …, 2020 - Elsevier
Abstract Generic Equatorial Diagnostic First Wall (GEDFW) as a plasma facing component of
ITER sustains heavy thermal load from plasma radiation and nuclear load. Cooling circuit of …

Engineering issues on the diagnostic port integration in ITER upper port 18

S Pak, L Bertalot, MS Cheon, T Giacomin… - Fusion Engineering and …, 2016 - Elsevier
Abstract The upper port# 18 (UP18) in ITER hosts three diagnostic systems: the neutron
activation system, the Vacuum Ultra-Violet spectrometer system, and the vertical neutron …