Monte Carlo modelling of external radiotherapy photon beams
F Verhaegen, J Seuntjens - Physics in medicine & biology, 2003 - iopscience.iop.org
An essential requirement for successful radiation therapy is that the discrepancies between
dose distributions calculated at the treatment planning stage and those delivered to the …
dose distributions calculated at the treatment planning stage and those delivered to the …
[HTML][HTML] A systematic review of nutrition recommendation systems: with focus on technical aspects
Background: Nutrition informatics has become a novel approach for registered dietitians to
practice in this field and make a profit for health care. Recommendation systems considered …
practice in this field and make a profit for health care. Recommendation systems considered …
[PDF][PDF] BEAMnrc users manual
DWO Rogers, B Walters, I Kawrakow - Nrc Report Pirs, 2009 - nrc-cnrc.github.io
Abstract BEAMnrc is a Monte Carlo simulation system (Med. Phys. 22, 1995, 503–524) for
modelling radiotherapy sources which was developed as part of the OMEGA project to …
modelling radiotherapy sources which was developed as part of the OMEGA project to …
Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code
D Sheikh‐Bagheri, DWO Rogers - Medical physics, 2002 - Wiley Online Library
A recent paper analyzed the sensitivity to various simulation parameters of the Monte Carlo
simulations of nine beams from three major manufacturers of commercial medical linear …
simulations of nine beams from three major manufacturers of commercial medical linear …
Efficiency improvements for ion chamber calculations in high energy photon beams
J Wulff, K Zink, I Kawrakow - Medical physics, 2008 - Wiley Online Library
This article presents the implementation of several variance reduction techniques that
dramatically improve the simulation efficiency of ion chamber dose and perturbation factor …
dramatically improve the simulation efficiency of ion chamber dose and perturbation factor …
Optical dosimetry of radiotherapy beams using Cherenkov radiation: the relationship between light emission and dose
Recent studies have proposed that light emitted by the Cherenkov effect may be used for a
number of radiation therapy dosimetry applications. There is a correlation between the …
number of radiation therapy dosimetry applications. There is a correlation between the …
Radiation characteristics of helical tomotherapy
R Jeraj, TR Mackie, J Balog, G Olivera… - Medical …, 2004 - Wiley Online Library
Helical tomotherapy is a dedicated intensity modulated radiation therapy (IMRT) system with
on‐board imaging capability (MVCT) and therefore differs from conventional treatment units …
on‐board imaging capability (MVCT) and therefore differs from conventional treatment units …
Monte Carlo simulated correction factors for machine specific reference field dose calibration and output factor measurement using fixed and iris collimators on the …
P Francescon, W Kilby, N Satariano… - Physics in Medicine & …, 2012 - iopscience.iop.org
Monte Carlo (MC) simulation of dose to water and dose to detector has been used to
calculate the correction factors needed for dose calibration and output factor measurements …
calculate the correction factors needed for dose calibration and output factor measurements …
Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX …
GX Ding - Physics in Medicine & Biology, 2002 - iopscience.iop.org
The purpose of this study is to provide detailed characteristics of incident photon beams for
different field sizes and beam energies. This information is critical to the future development …
different field sizes and beam energies. This information is critical to the future development …
Monte Carlo calculations of, the beam quality conversion factor
BR Muir, DWO Rogers - Medical physics, 2010 - Wiley Online Library
Purpose: To use EGSnrc Monte Carlo simulations to directly calculate beam quality
conversion factors,, for 32 cylindrical ionization chambers over a range of beam qualities …
conversion factors,, for 32 cylindrical ionization chambers over a range of beam qualities …