A review on factors that affect surface charge accumulation and charge-induced surface flashover

M Yuan, L Zou, Z Li, L Pang, T Zhao, L Zhang… - …, 2021 - iopscience.iop.org
The surface charge accumulation is very likely to trigger the surface flashover, which limits
the large-scale application of DC GIL/GIS. This article comprehensively reviews the effect of …

Long-Term Partial Discharge Behavior of Protrusion Defect in HVDC GIS

T Vu-Cong, C Toigo, F Jacquier… - … on Dielectrics and …, 2022 - ieeexplore.ieee.org
This article investigates the partial discharge (PD) behavior of protrusion defects in real-size
high-voltage direct current gas insulated switchgear (HVDC GIS) for SF6 and SF6 alternative …

Influence of insulating material properties on partial discharges at dc voltage

M Florkowski - Energies, 2020 - mdpi.com
Understanding a partial discharge mechanism at direct current (DC) is an actual research
topic that requires both modeling, simulations and measurements. This paper describes an …

Towards Generalizable Classification of Partial Discharges in Gas-Insulated HVDC Systems using Neural Networks: Protrusions and Particles

S Seitz, T Götz, C Lindenberg… - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
Undetected partial discharges (PDs) are a safety critical issue in high voltage (HV) gas-
insulated systems (GIS). While the diagnosis of PDs under AC voltage is well-established …

Partial discharge analysis and simulation using the consecutive pulses correlation method

O Kozák, J Pihera - Energies, 2021 - mdpi.com
The behaviour of partial discharge as consequences of an alternating current (AC) is
already well defined. AC partial discharges have completely different behaviour …

Outdoor Insulation and Gas-Insulated Switchgears

I Fofana, S Brettschneider - Energies, 2022 - mdpi.com
With the growth of the world's population and faster-developing industries, larger amounts of
electric energy are needed [1–6]. To reduce Joule losses at longer distances, voltages …

Classification of UHF Partial Discharge Signals in Gas-Insulated HVDC Systems Using Neural Networks

S Seitz, T Götz, C Lindenberg, R Tetzlaff… - arXiv preprint arXiv …, 2023 - arxiv.org
Undetected partial discharges (PDs) are a safety critical issue in high voltage (HV) gas
insulated systems (GIS). While the diagnosis of PDs under AC voltage is well-established …

Automatic optimization of gas insulated components based on the streamer inception criterion

F Lucchini, N Marconato, P Bettini - Electronics, 2021 - mdpi.com
Gas insulated transmission lines (GILs) are used in electrical systems mainly for power
transmission and High Voltage substation interconnection. In this paper, we focus on the …

Partial Discharge Characteristics of Fluoronitriles/CO2 and Trifluoroiodomethane/CO2 Gas Mixtures under DC Voltage

H Li, N Zebouchi, M Haddad… - … Conference on Electrical …, 2021 - ieeexplore.ieee.org
Due to the rapid development of DC power transmission technology, HVDC gas insulated
transmission lines (GIL) and gas insulated switchgear (GIS) are considered as potential …

The Effect of Long Term Corona Discharge on Protrusion Characteristics in C4F7N/CO2 and SF6

E Karimi, Z Jin, A Laso, M Mucha… - 2024 IEEE Electrical …, 2024 - ieeexplore.ieee.org
This study investigates the effect of long-term corona discharge on the physical and
chemical characteristics of protrusion defects in high-voltage alternating current for C 4 F 7 N …