Current concepts review-wear in total hip and knee replacements

TP Schmalzried, JJ Callaghan - JBJS, 1999 - journals.lww.com
Before the advent of total joint replacement, patients who had end-stage arthritis of the lower
extremities had unremitting pain and a greatly decreased functional capacity. In addition …

Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty

RW McCalden, DD Naudie, X Yuan, RB Bourne - JBJS, 2005 - journals.lww.com
All wear-measurement techniques assess femoral head penetration and therefore cannot
distinguish between true polyethylene wear and bedding-in. Multiple wear measurements …

Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene: a hip-simulator …

H McKellop, F Shen, B Lu, P Campbell, R Salovey - JBJS, 2000 - journals.lww.com
Background: Wear of ultra-high molecular weight polyethylene acetabular cups in hip
prostheses produces billions of submicrometer wear particles annually that can cause …

Average patient walking activity approaches 2 million cycles per year: pedometers under-record walking activity

M Silva, EF Shepherd, WO Jackson, FJ Dorey… - The Journal of …, 2002 - Elsevier
A two-dimensional accelerometer worn on the ankle (step activity monitor [SAM]; Prosthetic
Research Study, Seattle, WA) has been proved to be highly accurate for assessing walking …

Characterization of long-term femoral-head-penetration rates: association with and prediction of osteolysis

JE Dowd, CJ Sychterz, AM Young, CA Engh - JBJS, 2000 - journals.lww.com
Background: We examined the relationship between long-term femoral-head-penetration
patterns and osteolysis in a ten-year follow-up study of a well controlled patient population …

Results of Charnley total hip arthroplasty at a minimum of thirty years: a concise follow-up of a previous report

JJ Callaghan, JE Templeton, SS Liu, DR Pedersen… - JBJS, 2004 - journals.lww.com
The purpose of the current study was to update the results of a prospective, single-surgeon
series of primary Charnley total hip arthroplasties performed with cement. This investigation …

Assessment of polyethylene wear in total hip replacement

PA Devane, JG Horne - Clinical Orthopaedics and Related …, 1999 - journals.lww.com
The three-dimensional technique is a method for the measurement of polyethylene wear in
patients with total hip joint replacement. Application of image processing technology allows …

Twenty-five-year results after Charnley total hip arthroplasty in patients less than fifty years old: a concise follow-up of a previous report

JD Keener, JJ Callaghan, DD Goetz, DR Pederson… - JBJS, 2003 - journals.lww.com
We report the updated results for a previously evaluated cohort of patients who were less
than fifty years old when they underwent Charnley total hip arthroplasty with cement. The …

Revision of a Cemented Acetabular Component to a Cementless Acetabular Component: A Ten to Fourteen‐Year Follow‐up Study

JE Templeton, JJ Callaghan, DD Goetz, PM Sullivan… - JBJS, 2001 - journals.lww.com
Background: Although cementless acetabular components are routinely used in revision hip
surgery, few investigators have evaluated the retention and efficacy of these components in …

Activity level and wear in total knee arthroplasty: a study of autopsy retrieved specimens

CJ Lavernia, RJ Sierra, DS Hungerford… - The Journal of …, 2001 - Elsevier
We assessed the correlation between activity level, length of implantation (LOI), and wear in
total knee arthroplasty. Twenty-eight implants were retrieved at autopsy from 8 men and 15 …