The new clinical standard of integrated quadruple stress echocardiography with ABCD protocol

E Picano, Q Ciampi, K Wierzbowska-Drabik… - Cardiovascular …, 2018 - Springer
Background The detection of regional wall motion abnormalities is the cornerstone of stress
echocardiography. Today, stress echo shows increasing trends of utilization due to growing …

Practical guidance to reduce radiation exposure in electrophysiology applying ultra low-dose protocols: a European Heart Rhythm Association review

P Sommer, V Sciacca, M Anselmino, R Tilz… - Europace, 2023 - academic.oup.com
Interventional electrophysiology offers a great variety of treatment options to patients
suffering from symptomatic cardiac arrhythmia. Catheter ablation of supraventricular and …

Editor's Choice–European Society for Vascular Surgery (ESVS) 2023 clinical practice guidelines on radiation safety

B Modarai, S Haulon, E Ainsbury, D Böckler… - European journal of …, 2023 - ejves.com
The majority of studies investigating the effectiveness of radiation shields focus on
procedures performed by cardiologists. These studies are, nevertheless, relevant also for …

Safety and efficacy of zero fluoroscopy transseptal puncture with different approaches

T Baykaner, KK Quadros, A Thosani… - Pacing and Clinical …, 2020 - Wiley Online Library
Introduction Atrial fibrillation (AF) ablation requires access to the left atrium (LA) via
transseptal puncture (TP). TP is traditionally performed with fluoroscopic guidance. Use of …

The structural heart disease interventional imager rationale, skills and training: a position paper of the European Association of Cardiovascular Imaging

E Agricola, F Ancona, E Brochet, E Donal… - European Heart …, 2021 - academic.oup.com
Percutaneous therapeutic options for an increasing variety of structural heart diseases
(SHD) have grown dramatically. Within this context of continuous expansion of devices and …

Radiation awareness in an Italian multispecialist sample assessed with a web-based survey

M Giaccardi, M Anselmino, M Del Greco… - Acta …, 2021 - Taylor & Francis
Introduction The awareness of radiation doses and risks, also during interventional
cardiology procedures, is essential today in order to apply the risk-benefit assessment and …

A novel catheterization laboratory radiation shielding system: results of pre-clinical testing

SR Dixon, M Rabah, S Emerson, C Schultz… - Cardiovascular …, 2022 - Elsevier
Background This pre-clinical study evaluated the efficacy of a novel shielding system to
reduce scatter radiation in the cardiac catheterization laboratory. Methods Using a scatter …

New perforated radiation shield for anesthesiologists: Monte Carlo simulation of effects

A Yanagawa, T Takata, T Onimaru… - Journal of Radiation …, 2023 - academic.oup.com
Catheterization for structural heart disease (SHD) requires fluoroscopic guidance, which
exposes health care professionals to radiation exposure risk. Nevertheless, existing …

[HTML][HTML] Impact of active esophageal cooling on fluoroscopy usage during left atrial ablation

J Zagrodzky, S Bailey, S Shah… - The Journal of Innovations …, 2021 - ncbi.nlm.nih.gov
Risks to collateral structures exist with radiofrequency (RF) ablation of the left atrium to
obtain pulmonary vein isolation (PVI) for the treatment of atrial fibrillation. Passive luminal …

Efficacy of MAVIG X-ray protective drapes in reducing operator radiation dose in the cardiac catheterization laboratory: a randomized controlled trial

K McCutcheon, M Vanhaverbeke… - Circulation …, 2020 - Am Heart Assoc
Background: Interventional cardiologists are occupationally exposed to high doses of
ionizing radiation. The MAVIG X-ray protective drape (MXPD) is a commercially available …