Review of current intracranial aneurysm flow diversion technology and clinical use

S Dandapat, A Mendez-Ruiz… - Journal of …, 2021 - jnis.bmj.com
Endovascular treatment of intracranial aneurysms (IAs) has evolved considerably over the
past decades. The technological advances have been driven by the experience that coils fail …

Expanding indications for flow diverters: distal aneurysms, bifurcation aneurysms, small aneurysms, previously coiled aneurysms and clipped aneurysms, and carotid …

N Limbucci, G Leone, L Renieri, S Nappini… - …, 2020 - journals.lww.com
Flow diverter devices have gained wide acceptance for the treatment of unruptured
intracranial aneurysms. Most studies are based on the treatment of large aneurysms …

Flow diversion: a disruptive technology coming of age. Lessons learned and challenges for the future

A Enriquez-Marulanda, MM Young, P Taussky - Journal of Neurosurgery, 2023 - thejns.org
Intracranial aneurysm treatment has been revolutionized over the last decade with the
development of flow diversion technology. The use of this technology has evolved rapidly …

Flow diversion beyond the circle of Willis: endovascular aneurysm treatment in peripheral cerebral arteries employing a novel low-profile flow diverting stent

S Schob, KT Hoffmann, C Richter, P Bhogal… - Journal of …, 2019 - jnis.bmj.com
Background Flow diversion (FD) has emerged as superior minimally invasive therapy for
cerebral aneurysms. However, aneurysms of small peripheral vessel segments have not yet …

First clinical multicenter experience with the new Pipeline Vantage flow diverter

DF Vollherbst, HS Cekirge, I Saatci… - Journal of …, 2023 - jnis.bmj.com
Background Flow diversion is an innovative and increasingly used technique for the
treatment of intracranial aneurysms. New flow diverters (FDs) are being introduced to …

Pipeline flex embolisation device with shield technology for the treatment of patients with intracranial aneurysms: periprocedural and 6 month outcomes

J Yeomans, L Sandu, A Sastry - The Neuroradiology Journal, 2020 - journals.sagepub.com
Background and purpose The Pipeline Flex embolisation device with Shield Technology
(Pipeline Shield) is a novel flow diverter which reduces intra-vessel thrombogenicity. This …

Early clinical experience with the p48MW HPC and p64MW HPC flow diverters in the anterior circulation aneurysm using single anti-platelet treatment

P Bhogal, A Petrov, G Rentsenkhu… - Interventional …, 2022 - journals.sagepub.com
Background The p64MW HPC and p48MW HPC flow diverters have reduced
thrombogenicity due to hydrophilic coating. The purpose of this study was to evaluate its …

Delayed rupture of intracranial aneurysms after placement of intra-luminal flow diverter

K Hou, G Li, X Lv, B Xu, K Xu… - The Neuroradiology …, 2020 - journals.sagepub.com
Background Though flow diverter is a safe and efficient modality, some patients can
experience delayed aneurysmal rupture. The mechanism of delayed rupture is still obscure …

Trends in ruptured and unruptured aneurysmal treatment from 2010 to 2020: a focus on flow diversion

P Mirpuri, SI Khalid, LS McGuire, A Alaraj - World Neurosurgery, 2023 - Elsevier
Objective Flow diverters are a promising new tool in the neurosurgeon's arsenal for
aneurysm management. We sought to quantify the trends of flow diversion in comparison to …

Patient outcomes after treatment of brain aneurysm in small diameter vessels with the silk vista baby flow diverter: a systematic review

RA Hanel, GM Cortez, VHC Benalia… - Interventional …, 2024 - journals.sagepub.com
Background The Silk Vista Baby (SVB, BALT) is a first-in-class flow-diverter device delivered
using a 0.017” microcatheter, designed for the treatment of intracranial aneurysms, including …