CMOS electrochemical instrumentation for biosensor microsystems: A review

H Li, X Liu, L Li, X Mu, R Genov, AJ Mason - Sensors, 2016 - mdpi.com
Modern biosensors play a critical role in healthcare and have a quickly growing commercial
market. Compared to traditional optical-based sensing, electrochemical biosensors are …

Cheapstat: An open-source,“do-it-yourself” potentiostat for analytical and educational applications

AA Rowe, AJ Bonham, RJ White, MP Zimmer… - PloS one, 2011 - journals.plos.org
Although potentiostats are the foundation of modern electrochemical research, they have
seen relatively little application in resource poor settings, such as undergraduate laboratory …

A wireless-implantable microsystem for continuous blood glucose monitoring

MM Ahmadi, GA Jullien - IEEE transactions on Biomedical …, 2009 - ieeexplore.ieee.org
A remotely powered implantable microsystem for continuous blood glucose monitoring is
presented. The microsystem consists of a microfabricated glucose biosensor flip-chip …

Current-mirror-based potentiostats for three-electrode amperometric electrochemical sensors

MM Ahmadi, GA Jullien - … on Circuits and Systems I: Regular …, 2008 - ieeexplore.ieee.org
We present a new circuit topology for potentiostats that interface with three-electrode
amperometric electrochemical sensors. In this new topology, a current-copying circuit, eg, a …

PSoC-Stat: A single chip open source potentiostat based on a Programmable System on a Chip

P Lopin, KV Lopin - PloS one, 2018 - journals.plos.org
In this paper we demonstrate a potentiostat built with a single commercially available
integrated circuit (IC) that does not require any external electronic components to perform …

VLSI potentiostat array with oversampling gain modulation for wide-range neurotransmitter sensing

M Stanacevic, K Murari, A Rege… - … Circuits and Systems, 2007 - ieeexplore.ieee.org
A 16-channel current-measuring very large-scale integration (VLSI) sensor array system for
highly sensitive electrochemical detection of electroactive neurotransmiters like dopamine …

CMOS neurotransmitter microarray: 96-channel integrated potentiostat with on-die microsensors

MH Nazari, H Mazhab-Jafari, L Leng… - IEEE transactions on …, 2012 - ieeexplore.ieee.org
A 8 \,*\, 12 array of integrated potentiostats for on-CMOS neurotransmitter imaging is
presented. Each potentiostat channel measures bidirectional redox currents proportional to …

Noise analysis and performance comparison of low current measurement systems for biomedical applications

D Kim, B Goldstein, W Tang, FJ Sigworth… - IEEE transactions on …, 2012 - ieeexplore.ieee.org
In this paper, we report on the noise analysis of low current measurement systems for
biomedical applications and their fundamental limits. We analyzed resistive feedback …

Amperometric electrochemical microsystem for a miniaturized protein biosensor array

C Yang, Y Huang, BL Hassler… - IEEE transactions on …, 2009 - ieeexplore.ieee.org
Protein-based bioelectrochemical interfaces offer great potential for rapid detection,
continuous use, and miniaturized sensor arrays. This paper introduces a microsystem …

A review of electrochemical electrodes and readout interface designs for biosensors

Y Ma, Y Deng, C Xie, B Zhang, B Shen… - IEEE Open Journal …, 2022 - ieeexplore.ieee.org
Electrochemical detection is widely used in biosensing fields, such as medical diagnosis
and health monitoring due to its real-time response and high accuracy. Both passive and …