[HTML][HTML] Dose optimisation in paediatric radiography–Using regression models to investigate the relative impact of acquisition factors on image quality and radiation …

AM Ali, P Hogg, A England - Physica Medica, 2019 - Elsevier
Objective To investigate the optimum pelvis X-ray acquisition factors for a 10-year-old child.
Secondly, to evaluate the impact of each acquisition factor on image quality (IQ) and …

Impact of acquisition parameters on dose and image quality optimisation in paediatric pelvis radiography—A phantom study

AM Ali, P Hogg, M Abuzaid, A England - European Journal of Radiology, 2019 - Elsevier
Purpose Within paediatric pelvis imaging there is a lack of systematic dose optimisation
studies which consider age and size variations. This paper presents data from dose …

Radiation dose optimisation for conventional imaging in infants and newborns using automatic dose management software: an application of the new 2013/59 …

L Alejo, E Corredoira, F Sánchez-Muñoz… - The British Journal of …, 2018 - academic.oup.com
 Objective: The new 2013/59 EURATOM Directive (ED) demands dosimetric optimisation
procedures without undue delay. The aim of this study was to optimise paediatric …

Radiographer research in radiation protection: National and European perspectives

G Paulo - Radiography, 2020 - Elsevier
The author of this paper gives an overview about the evolution of radiography education in
Portugal and reflects about the importance of Radiographer-led research, especially in the …

[图书][B] An investigation into methods for dose optimisation for paediatric AP pelvis projections when considering size variations

AHM Ali - 2019 - search.proquest.com
Purpose There is a lack of literature on paediatric x-ray dose optimisation; this is especially
true for pelvis radiography using digital systems. Various reasons exist for this including the …

Optimisation of tube voltage range (kVp) for AP abdomen, pelvis and spine imaging of average patients with a digital radiography (DR) imaging system using a …

CS Moore, T Wood, S Balcam, L Needler… - The British Journal of …, 2020 - academic.oup.com
Objectives: To investigate via computer simulation, an optimised tube voltage (kVp) range
for caesium iodide (CsI)-based digital radiography (DR) of the abdomen, pelvis and lumbar …

Optimisation and establishment of Diagnostic Reference Levels in paediatric plain radiography

GNN Paulo - 2015 - search.proquest.com
Purpose: This study aimed to propose Diagnostic Reference Levels (DRLs) in paediatric
plain radiography and to optimise the most frequent paediatric plain radiography …

Thema: Qualität der pädiatrischen ap-/pa-Röntgenaufnahmen des Thorax im Kontext der aktuellen Leitlinien der Europäischen Kommission-Realisierbarkeit in der …

F Schmidt - 2019 - epub.ub.uni-greifswald.de
Die Gruppe der Kinder und Jugendlichen stellt in der Radiologie die schwierigste
Patientengruppe dar. Aufgrund ihrer hohen Strahlensensibilität, der alterstechnisch …

[PDF][PDF] Thema: Qualität der pädiatrischen ap-/pa-Röntgenaufnahmen des Thorax im Kontext der aktuellen Leitlinien der Europäischen Kommission

F Schmidt - epub.ub.uni-greifswald.de
In einer Populationsstudie in den USA wurde festgestellt, dass Kinder, die das 18.
Lebensjahr erreicht haben, durchschnittlich sieben Röntgenaufnahmen erhalten hatten (1) …

Aplicación de la Directiva 2013/59 EURATOM en procedimientos pediátricos de radiología digital y cardiología intervencionista

L Alejo Luque - 2019 - docta.ucm.es
Aplicación de la Directiva 2013/59 EURATOM en procedimientos pediátricos de radiología
digital y cardiología intervencionist Page 1 UNIVERSIDAD COMPLUTENSE DE MADRID …