Neutron contamination in radiotherapy processes: a review study
N Banaee, K Goodarzi… - Journal of Radiation …, 2021 - academic.oup.com
Using high-energy photon beams is one of the most practical methods in radiotherapy
treatment of cases in deep site located tumors. In such treatments, neutron contamination …
treatment of cases in deep site located tumors. In such treatments, neutron contamination …
Neutron dose equivalent and neutron spectra in tissue for clinical linacs operating at 15, 18 and 20 MV
SA Martinez-Ovalle, R Barquero… - Radiation protection …, 2011 - academic.oup.com
In this work, the dose equivalent due to photoneutrons and the neutron spectra in tissue was
calculated for various linacs (Varian Clinac 2100C, Elekta Inor, Elekta SL25 and Siemens …
calculated for various linacs (Varian Clinac 2100C, Elekta Inor, Elekta SL25 and Siemens …
Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations
HA Nedaie, H Darestani, N Banaee… - Journal of Medical …, 2014 - journals.lww.com
High-energy linacs produce secondary particles such as neutrons (photoneutron
production). The neutrons have the important role during treatment with high energy photons …
production). The neutrons have the important role during treatment with high energy photons …
Monte Carlo estimation of photoneutrons spectra and dose equivalent around an 18 MV medical linear accelerator
A Alem-Bezoubiri, F Bezoubiri, A Badreddine… - Radiation Physics and …, 2014 - Elsevier
A fully detailed Monte Carlo geometrical model of an 18 MV Varian Clinac 2100C medical
linear accelerator, lodged at Blida Anti-Cancer Centre in Algeria, was developed during this …
linear accelerator, lodged at Blida Anti-Cancer Centre in Algeria, was developed during this …
Neutron spectrometry and determination of neutron contamination around the 15 MV Siemens Primus LINAC
N Mohammadi, H Miri-Hakimabad… - … of radioanalytical and …, 2015 - Springer
Despite the importance of photoneutrons doses produced in the high-energy linear
accelerators, currently they are not considered in the treatment planning systems. Therefore …
accelerators, currently they are not considered in the treatment planning systems. Therefore …
[HTML][HTML] 医用电子直线加速器感生放射性的测量和分析
贾斌, 朱建国, 杨淑慧, 牛菲, 卢峰, 张琳, 闵楠 - 中国辐射卫生, 2021 - html.rhhz.net
目的通过对医用电子直线加速器感生放射性进行测量, 研究感生放射性冷却规律, 并为评估患者,
医务人员及公众额外受照剂量提供基础数据. 方法采用automess—6150AD6/H+ 6150AD-b/H …
医务人员及公众额外受照剂量提供基础数据. 方法采用automess—6150AD6/H+ 6150AD-b/H …
Analysis of improved neutron activation technique using thick foils for application on medical LINAC environment
An improved neutron activation technique is analyzed that can be used for the
characterization of the neutron field in low neutron flux environments, such as medical …
characterization of the neutron field in low neutron flux environments, such as medical …
Measurement of neutron dose in the compensator IMRT treatment
A radiation treatment delivery technique, intensity modulated radiation therapy (IMRT), has
found widespread use in the treatment of cancers. One of IMRT implementing methods is …
found widespread use in the treatment of cancers. One of IMRT implementing methods is …
Geant4 simulations on medical Linac operation at 18 MV: Experimental validation based on activation foils
The operation of a medical linear accelerator was simulated using the Geant4 code
regarding to study the characteristics of an 18 MeV photon beam. Simulations showed that …
regarding to study the characteristics of an 18 MeV photon beam. Simulations showed that …
Measurement of the secondary neutron dose distribution from the LET spectrum of recoils using the CR-39 plastic nuclear track detector in 10áMV X-ray medical …
T Fujibuchi, S Kodaira, F Sawaguchi, Y Abe… - Nuclear Instruments and …, 2015 - Elsevier
We measured the recoil charged particles from secondary neutrons produced by the
photonuclear reaction in a water phantom from a 10-MV photon beam from medical linacs …
photonuclear reaction in a water phantom from a 10-MV photon beam from medical linacs …