Study of the effect of laponite on Fricke xylenol orange gel dosimeter by optical techniques
S Gallo, L Cremonesi, G Gambarini, L Ianni… - Sensors and Actuators B …, 2018 - Elsevier
Optical absorbance and dynamic light scattering studies of Fricke xylenol orange gel
dosimeters loaded with laponite were carried out with the aim to investigate possible effects …
dosimeters loaded with laponite were carried out with the aim to investigate possible effects …
Dosimetric properties of sulfosalicylic acid-ferrous-polyvinyl alcohol-glutaraldehyde hydrogel dosimeters using magnetic and optical techniques
A chemically cross-linked transparent hydrogel dosimeter is prepared with ferrous
ammonium sulfate (FAS), polyvinyl alcohol (PVA), 5-Sulfosalicylic acid (SSA), and cross …
ammonium sulfate (FAS), polyvinyl alcohol (PVA), 5-Sulfosalicylic acid (SSA), and cross …
A polystyrene film dosimeter containing dithizone dye for high dose applications of gamma-ray source
A dosimeters made up of polystyrene (PS) binder containing different concentrations of
dithizone (Dz) dye are investigated for high dose applications. Dyed PS film dosimeters …
dithizone (Dz) dye are investigated for high dose applications. Dyed PS film dosimeters …
1, 10-Bis (diphenylamino)-4, 6-decadiyne as an active component of a radiochromic film dosimeter
YS Soliman, AA Abdel-Fattah, SG Dutremez - Radiation Physics and …, 2021 - Elsevier
Gamma-irradiation processes are very important tools for minimizing microbial load in dry
food, inhibiting the proliferation of T-lymphocytes in blood, and for the sterilization of medical …
food, inhibiting the proliferation of T-lymphocytes in blood, and for the sterilization of medical …
A radiation-sensitive monomer of 2, 4-hexadiyn-1, 6-bis (p-toluene sulphonyl urethane) in PVA as a radiochromic film dosimeter
Abstract A conjugated monomer 2, 4-hexadiyn-1, 6-bis (p-toluene sulphonyl
urethane)(HDTU) was synthesized. Thereafter, it was incorporated into polyvinyl alcohol …
urethane)(HDTU) was synthesized. Thereafter, it was incorporated into polyvinyl alcohol …
Radiochromic film containing poly (hexa-2, 4-diynylene adipate) as a radiation dosimeter
A radiation-sensitive polymer poly (hexa-2, 4-diynylene adipate)(PHDA) was synthesized
and incorporated into polyvinyl butyral films for radiation dose measurements in the 0.5–60 …
and incorporated into polyvinyl butyral films for radiation dose measurements in the 0.5–60 …
Performance improvement of pentacosa-diynoic acid label dosimeter for radiation processing technology
AA Abdel-Fattah, YS Soliman - Radiation Physics and Chemistry, 2017 - Elsevier
Abstract A radiation sensitive material, 10, 12-pentacosa-diynoic acid (PCDA), was
incorporated into polyvinyl butyral (PVB) films to develop indicators/dosimeters for blood and …
incorporated into polyvinyl butyral (PVB) films to develop indicators/dosimeters for blood and …
Synthesis of a metal chelating monomer for radiation polymer dosimetry
To enhance the performance of polymeric dosimeters it is necessary to design novel
formulations considering the mechanisms that register the absorbed dose (eg induced …
formulations considering the mechanisms that register the absorbed dose (eg induced …
Radiochromic film label made from chitosan and Taraxacum officinale leaf extract
Monitoring the dose of gamma-ray radiation is important in the healthcare field. A simple
indicator for dose monitoring is provided by radiochromic labels. This paper reports the …
indicator for dose monitoring is provided by radiochromic labels. This paper reports the …
Development and dosimetric characterization of novel amide substituted diacetylene based radiochromic films for medical radiation dosimetry
A Mittal, G Natanasabapathi, A Verma… - Radiation Physics and …, 2021 - Elsevier
Radiochromic films are one of the most suitable dosimetry tools to perform two-dimensional
dose measurement and dose verification in radiotherapy. In this work, a novel polymer …
dose measurement and dose verification in radiotherapy. In this work, a novel polymer …