Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
Over the past 30 years, the application of carrierbased ion-selective electrodes (ISEs) has
evolved to a well-established routine analytical technique. The College of American …
evolved to a well-established routine analytical technique. The College of American …
Highly reproducible solid contact ion selective electrodes: Emerging opportunities for potentiometry–A review
The solid contact ion-selective electrodes (SC-ISEs) have been extensively studied in the
field of ion sensing as they offer the possibility of miniaturization, are relatively inexpensive …
field of ion sensing as they offer the possibility of miniaturization, are relatively inexpensive …
Scanning electrochemical microscopy
FRF Fan, B Liu, J Mauzeroll - Handbook of electrochemistry, 2007 - Elsevier
Publisher Summary The chapter discusses various techniques and applications of scanning
electrochemical microscopy (SECM), one of the scanning probe microscopies (SPM) in …
electrochemical microscopy (SECM), one of the scanning probe microscopies (SPM) in …
[图书][B] Encyclopedia of surface and colloid science
AT Hubbard - 2002 - books.google.com
This comprehensive reference collects fundamental theories and recent research from a
wide range of fields including biology, biochemistry, physics, applied mathematics, and …
wide range of fields including biology, biochemistry, physics, applied mathematics, and …
Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensors
Lipophilic borate salts are frequently used as anionic additives in potentiometric and optical
cation-selective sensors based on solvent polymeric membranes. The lifetime of such …
cation-selective sensors based on solvent polymeric membranes. The lifetime of such …
A cobalt (II)-selective PVC membrane based on a Schiff base complex of N, N′-bis (salicylidene)-3, 4-diaminotoluene
A new PVC membrane electrode for Co2+ based on N, N′-bis (salicylidene)-3, 4-
diaminotoluene, an excellent neutral carrier, has been fabricated using sodium …
diaminotoluene, an excellent neutral carrier, has been fabricated using sodium …
A review on the corrosion resistance of electroless Ni-P based composite coatings and electrochemical corrosion testing methods
This paper aims to review the impact of different factors influencing the corrosion resistance
of electroless Ni-P based coatings. Emphasis has been given onto the impact of phosphorus …
of electroless Ni-P based coatings. Emphasis has been given onto the impact of phosphorus …
Flexible (Kapton-based) microsensor arrays of high stability for cardiovascular applications
E Lindner, VV Cosofret, S Ufer, RP Buck… - Journal of the …, 1993 - pubs.rsc.org
The design, fabrication and performance characteristics of Kapton-based planar mini and
semimicro potentiometric sensors with an Ag/AgCl or a quinhydrone-based redox internal …
semimicro potentiometric sensors with an Ag/AgCl or a quinhydrone-based redox internal …
Performance evaluation criteria for preparation and measurement of macro-and microfabricated ion-selective electrodes (IUPAC Technical Report)
E Lindner, Y Umezawa - Pure and Applied Chemistry, 2008 - degruyter.com
Over the last 30 years, IUPAC published several documents with the goal of achieving
standardized nomenclature and methodology for potentiometric ion-selective electrodes …
standardized nomenclature and methodology for potentiometric ion-selective electrodes …
Schiff's bases and crown ethers as supramolecular sensing materials in the construction of potentiometric membrane sensors
Ionophore incorporated PVC membrane sensors are well-established analytical tools
routinely used for the selective and direct measurement of a wide variety of different ions in …
routinely used for the selective and direct measurement of a wide variety of different ions in …