Effects of electromagnetic interference on underground pipelines caused by the operation of high voltage AC traction systems: The impact of harmonics

CA Charalambous, A Demetriou… - … on Power Delivery, 2018 - ieeexplore.ieee.org
When evaluating the risks resulting from the effects of electromagnetic interference (EMI) on
buried pipelines running near ac electrified traction systems, the harmonic distortion in …

Transient induced voltages on aboveground pipelines parallel to overhead transmission lines

TA Papadopoulos, ZG Datsios, AI Chrysochos… - Electric Power Systems …, 2023 - Elsevier
Lightning strikes to conductors of overhead lines may cause high transient induced voltages
at neighbouring pipelines. Thus, the computation of these voltages is important for the safe …

Influence of lossy ground on high-frequency induced voltages on aboveground pipelines by nearby overhead transmission lines

AG Martins-Britto, TA Papadopoulos… - IEEE Transactions …, 2022 - ieeexplore.ieee.org
The electromagnetic interference (EMI) of overhead transmission lines (OHLs) to
aboveground pipelines sharing the same right-of-ways has been a research topic for many …

Mitigation of high voltage induction effect on ICCP system of gas pipelines: a field case study

R Ismail, A Hasibuan, M Isa… - TELKOMNIKA …, 2019 - telkomnika.uad.ac.id
An analysis of the high voltage induction effect on the impressed current cathodic protection
(ICCP) system on pipelines parallel toward high voltage power lines was employed in this …

Corrosive effects of the electromagnetic induction caused by the high voltage power lines on buried X70 steel pipelines

M Ouadah, O Touhami, R Ibtiouen… - International Journal of …, 2017 - Elsevier
This paper diagnoses the corrosive effects of the electromagnetic induction caused by
double circuit high voltage power lines (HVPL) on the buried X70 steel pipelines. To achieve …

Analysis of coupling effects on overhead VSC-HVDC transmission lines from AC lines with shared right of way

H Ding, Y Zhang, AM Gole… - … on Power Delivery, 2010 - ieeexplore.ieee.org
The coupling of fundamental frequency voltages and currents on voltage-source converter
(VSC)-HVDC overhead transmission lines from neighboring ac lines is analyzed. The …

Calculation of overvoltage on nearby underground metal pipeline due to the lightning strike on UHV AC transmission line tower

L Qi, H Yuan, Y Wu, X Cui - Electric Power Systems Research, 2013 - Elsevier
Making use of EMTP, the transient simulation of the currents along the towers and ground
wires is performed when the lightning strikes the tower of the power transmission line. The …

Modeling of the KOH-Polarization cells for mitigating the induced AC voltage in the metallic pipelines

MA Al-Gabalawy, MA Mostafa, AS Hamza, SA Hussien - Heliyon, 2020 - cell.com
The problem of AC corrosion remains motivating for researchers because many factors
influence the corrosion rate for buried pipelines due to the interference with overhead high …

Analysis of short-circuit current characteristics and its distribution of artificial grounding faults on DC transmission lines

C Huang, B Zhang, Y Ma, F Zhou… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
Grounding faults are common faults on dc transmission lines. Characteristics of the short-
circuit current, such as amplitude and frequency, and its following distribution are very …

Transient analysis of inductive induced voltage between power line and nearby pipeline

X Wu, H Zhang, GG Karady - International Journal of Electrical Power & …, 2017 - Elsevier
Among the available literature on electromagnetic interference between high voltage power
lines and nearby pipelines, the topic of transient induced voltage on the pipelines are rarely …