Improvement of post-fault performance of a cascaded H-bridge multilevel inverter

S Ouni, MR Zolghadri, M Khodabandeh… - IEEE Transactions …, 2016 - ieeexplore.ieee.org
This paper is focused on improving the post-fault performance of cascaded H-bridge
multilevel inverters by decreasing the common-mode voltage. First, an algorithm is proposed …

A new postfault control method for CHB inverter to increase maximum output voltage

S Ouni, M Narimani, Z Cheng… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
In this article, a new postfault control algorithm for cascaded H-bridge (CHB) multilevel
inverter is proposed to increase the maximum available output voltage under semiconductor …

A fast and simple method to detect short circuit fault in cascaded H-bridge multilevel inverter

S Ouni, J Rodriguez, M Shahbazi… - 2015 IEEE …, 2015 - ieeexplore.ieee.org
Fault detection is one of the most important tasks in fault tolerant converters. In this paper, a
new method is proposed to detect the faulty cell in a cascaded H-bridge multilevel inverter …

A new fault-tolerant control method for cascaded H-bridge multilevel inverter to increase maximum output voltage

S Ouni, M Narimani, NR Zargari… - 2019 IEEE energy …, 2019 - ieeexplore.ieee.org
In this paper, a new fault-tolerant control algorithm for Cascaded H-Bridge Multilevel Inverter
is proposed to increase the maximum available voltage under faulty conditions. In this …

Fast detection of open-switch fault in cascaded H-Bridge multilevel converter

M Shahbazi, MR Zolghadri - The 6th Power Electronics, Drive …, 2015 - ieeexplore.ieee.org
Cascaded H-Bridge converter has recently been utilized in different high-power applications
due to its modular and simple structure. In order to have a balanced operation after a fault …

Reduction of common-mode voltage in cascaded H-bridge inverter under faulty conditions

A Raki, Y Neyshabouri, H Iman-Eini… - 2022 30th …, 2022 - ieeexplore.ieee.org
This paper proposes a new fault-tolerant method for cascaded H-bridge multilevel inverters
(CHB-MLIs) to reduce the common-mode voltage (CMV) and improve its performance under …

Quick diagnosis of short circuit faults in cascaded H-bridge multilevel inverters using FPGA

S Ouni, MR Zolghadri, J Rodriguez… - Journal of power …, 2017 - koreascience.kr
Fast and accurate fault detection is the primary step and one of the most important tasks in
fault tolerant converters. In this paper, a fast and simple method is proposed to detect and …

Fault-tolerant control for a flexible group battery energy storage system based on cascaded multilevel converters

J Song, W Zhang, H Liang, J Jiang, W Yu - Energies, 2018 - mdpi.com
A flexible group battery energy storage system (FGBESS) based on cascaded multilevel
converters is attractive for renewable power generation applications because of its high …

A decision algorithm to select a proper control method for a cascaded multilevel inverter under faulty condition

S Ouni, AU Schmeisser, MR Zolghadri… - IECON 2015-41st …, 2015 - ieeexplore.ieee.org
Fault tolerant ability is one of the most important tasks in high power converters. In this
paper, a comparison between conventional fault tolerant methods is done for four applicable …

Single phase five level Transistor Clamped inverter with multi-band hysteresis current control

R Choudhary, I Sarkar - 2016 IEEE 6th International …, 2016 - ieeexplore.ieee.org
Multi-band hysteresis current control of five level Transistor Clamped H-bridge (TCHB)
inverter using symmetric multiband hysteresis current control (MB HCC) is presented in this …