A review of active filters for power quality improvement
B Singh, K Al-Haddad… - IEEE transactions on …, 1999 - ieeexplore.ieee.org
Active filtering of electric power has now become a mature technology for harmonic and
reactive power compensation in two-wire (single phase), three-wire (three phase without …
reactive power compensation in two-wire (single phase), three-wire (three phase without …
[图书][B] Electric power distribution handbook
TA Short - 2003 - taylorfrancis.com
Of the... big three... components of the electricity infrastructure, distribution typically gets the
least attention, and no thorough, up-to-date treatment of the subject has been published in …
least attention, and no thorough, up-to-date treatment of the subject has been published in …
Comprehensive study of DSTATCOM configurations
In this paper, different Distribution Static Compensators (DSTATCOMs) topologies, state of
the art, their performance, design considerations, future developments, and potential …
the art, their performance, design considerations, future developments, and potential …
Feedback linearization of a single-phase active power filter via sliding mode control
The aim of this work is the application of the feedback linearization theory to a single-phase
shunt active power filter, since this technique has been successfully applied to other areas of …
shunt active power filter, since this technique has been successfully applied to other areas of …
[图书][B] Distribution reliability and power quality
L Taylor, TA Short - 2018 - taylorfrancis.com
Power distribution and quality remain the key challenges facing the electrical utilities
industry. Technology alone cannot provide a solution to power quality problems, and there …
industry. Technology alone cannot provide a solution to power quality problems, and there …
Effects of nonlinear loads on optimal capacitor placement in radial feeders
Y Baghzouz - IEEE Transactions on Power Delivery, 1991 - ieeexplore.ieee.org
The nonlinear portion of electrical loads has increased significantly in recent years.
Harmonic currents injected by these loads into the distribution system should be considered …
Harmonic currents injected by these loads into the distribution system should be considered …
Series active power filter compensates current harmonics and voltage unbalance simultaneously
An active power filter connected in series to the power distribution system is presented and
analysed. The series active power filter is implemented with a three-phase PWM voltage …
analysed. The series active power filter is implemented with a three-phase PWM voltage …
A series active power filter which compensates current harmonics and voltage unbalance simultaneously
An active power filter connected in series to the power distribution system is presented and
analyzed in this paper. The series active power filter is implemented with a PWM voltage …
analyzed in this paper. The series active power filter is implemented with a PWM voltage …
Harmonics estimation and modeling of residential and commercial loads
RD Patidar, SP Singh - 2009 International Conference on …, 2009 - ieeexplore.ieee.org
The distortion in the voltage and current waveforms deteriorates the performance of the
equipment/devices connected in the distribution systems. The analysis of the harmonics is …
equipment/devices connected in the distribution systems. The analysis of the harmonics is …
Distribution system harmonic filter planning
TH Ortmeyer, T Hiyama - IEEE Transactions on Power Delivery, 1996 - ieeexplore.ieee.org
A planning methodology for distribution system harmonic filtering is proposed. The method
is intended for use on radial distribution systems with no large harmonic sources. It is …
is intended for use on radial distribution systems with no large harmonic sources. It is …