Spectral CT imaging: technical principles of dual-energy CT and multi-energy photon-counting CT

J Greffier, N Villani, D Defez, D Dabli… - Diagnostic and …, 2023 - Elsevier
Spectral computed tomography (CT) imaging encompasses a unique generation of CT
systems based on a simple principle that makes use of the energy-dependent information …

Contribution of an artificial intelligence deep-learning reconstruction algorithm for dose optimization in lumbar spine CT examination: A phantom study

J Greffier, J Frandon, Q Durand, T Kammoun… - Diagnostic and …, 2023 - Elsevier
Purpose The purpose of this study was to assess the impact of the new artificial intelligence
deep-learning reconstruction (AI-DLR) algorithm on image quality and radiation dose …

[HTML][HTML] Ultra-high-resolution CT of the temporal bone: comparison between deep learning reconstruction and hybrid and model-based iterative reconstruction

A Beysang, N Villani, F Boubaker, U Puel… - Diagnostic and …, 2024 - Elsevier
Purpose The purpose of this study was to evaluate the ability of ultra-high-resolution
computed tomography (UHR-CT) to assess stapes and chorda tympani nerve anatomy …

Comparison of two deep-learning image reconstruction algorithms on cardiac CT images: A phantom study

J Greffier, M Pastor, S Si-Mohamed… - Diagnostic and …, 2024 - Elsevier
Purpose The purpose of this study was to compare the performance of Precise IQ Engine
(PIQE) and Advanced intelligent Clear-IQ Engine (AiCE) algorithms on image-quality …

Impact of phantom size on low-energy virtual monoenergetic images of three dual-energy CT platforms

J Greffier, C Van Ngoc Ty, I Fitton, J Frandon, JP Beregi… - Diagnostics, 2023 - mdpi.com
The purpose of this study was to compare the quality of low-energy virtual monoenergetic
images (VMIs) obtained with three Dual-Energy CT (DECT) platforms according to the …

Impact of tin filter on the image quality of ultra-low dose chest CT: A phantom study on three CT systems

J Greffier, I Fitton, CVN Ty, J Frandon, JP Beregi… - Diagnostic and …, 2023 - Elsevier
Purpose The purpose of this study was to assess the impact of a tin filter on the image
quality of ultra-low dose (ULD) chest computed tomography (CT) on three different CT …

Abdominal image quality and dose reduction with energy-integrating or photon-counting detectors dual-source CT: A phantom study

J Greffier, D Dabli, S Faby, M Pastor, C Croisille… - Diagnostic and …, 2024 - Elsevier
Purpose The purpose of this study was to assess image-quality and dose reduction potential
using a photon-counting computed tomography (PCCT) system by comparison with two …

Task-Based Image Quality Assessment Comparing Classical and Iterative Cone Beam CT Images on Halcyon®

M Lassot-Buys, R Verstraet, D Dabli, G Moliner… - Diagnostics, 2023 - mdpi.com
Background: Despite the development of iterative reconstruction (IR) in diagnostic imaging,
CBCT are generally reconstructed with filtered back projection (FBP) in radiotherapy. Varian …

Cross-domain Denoising for Low-dose Multi-frame Spiral Computed Tomography

Y Lu, Z Xu, MH Choi, J Kim… - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
Computed tomography (CT) has been used worldwide as a non-invasive test to assist in
diagnosis. However, the ionizing nature of X-ray exposure raises concerns about potential …

[PDF][PDF] IndoQCT: A platform for automated CT image quality assessment

C Anam, A Naufal, WS Budi, H Sutanto… - MEDICAL …, 2023 - researchgate.net
The quality control (QC) procedure of computed tomography (CT) is an important task to be
regularly performed. It consists of daily, monthly, and annual tasks. Each procedure can be …