Single-phase common-ground dual-buck inverters with no leakage current
This article presents two unique common-ground high-reliability dual-buck single-phase
inverters suitable for photovoltaic applications. The proposed inverters directly connect the …
inverters suitable for photovoltaic applications. The proposed inverters directly connect the …
Implementation of active NPC circuits in transformer-less single-phase inverter with low leakage current
Transformer-less grid-connected photovoltaic (PV) systems face the challenge of keeping
low leakage current due to their nonisolation configurations. To better attenuate the leakage …
low leakage current due to their nonisolation configurations. To better attenuate the leakage …
Two-stage transformerless dual-buck PV grid-connected inverters with high efficiency
L Zhang, F Jiang, D Xu, K Sun, Y Hao… - Chinese Journal of …, 2018 - ieeexplore.ieee.org
A semi-two-stage common-ground-type transformerless dual-buck-based grid-connected
inverter is proposed in this paper. The common-ground-type topology can eliminate …
inverter is proposed in this paper. The common-ground-type topology can eliminate …
Bidirectional transformerless EV charging system with low device cost and leakage current
In electric vehicles (EV), the charging circuit is an important component which needs to be
carefully designed. This research proposes a novel concept to reconfigure the traction circuit …
carefully designed. This research proposes a novel concept to reconfigure the traction circuit …
Bidirectional transformerless EV charging system via reconfiguration of 4× 4 drivetrain
Electric vehicles (EV) are developing fast and EV ownerships are increasing rapidly. In the
EV system, the electric traction inverter and the charging converter are two important …
EV system, the electric traction inverter and the charging converter are two important …
A dual-buck inverter with H5 configuration for photovoltaic grid-tied applications
Y Hao, L Zhang, F Jiang, Q Chen - IECON 2018-44th Annual …, 2018 - ieeexplore.ieee.org
In order to solve the problem of leakage current in the topology of transformerless
photovoltaic (PV) grid-connected inverter, this paper proposes a high reliability dual-buck …
photovoltaic (PV) grid-connected inverter, this paper proposes a high reliability dual-buck …
Half-cycle control method of the bidirectional three-phase dual-buck inverter without zero-crossing distortion
X Zheng, L Zhang, X Liu, Y He, J Shi… - IEEE Journal of …, 2020 - ieeexplore.ieee.org
The dual-buck inverter (DBI) does not have a shoot-through problem, and thus, the
harmonics caused by the dead-time can be avoided. Besides, the DBI of half-cycle control …
harmonics caused by the dead-time can be avoided. Besides, the DBI of half-cycle control …
Circuit Structure and Control Method to Reduce Size and Harmonic Distortion of Interleaved Dual Buck Inverter
MG Cho, SH Lee, HS Lee, YG Choi, B Kang - Energies, 2020 - mdpi.com
A new circuit structure and control method for a high power interleaved dual-buck inverter
are proposed. The proposed inverter consists of six switches, four diodes and two inductors …
are proposed. The proposed inverter consists of six switches, four diodes and two inductors …