A programmable System-on-Chip based digital pulse processing for high resolution X-ray spectroscopy

A Cicuttin, ML Crespo, KS Mannatunga… - … on Advances in …, 2016 - ieeexplore.ieee.org
It is described the global architecture of a digital pulse processing system for high resolution
X-Ray spectroscopy based on single photon detection and photon energy measurement …

Data Analysis and Filter Optimization for Pulse-Amplitude Measurement: A Case Study on High-Resolution X-ray Spectroscopy

KS Mannatunga, B Valinoti, W Florian Samayoa… - Sensors, 2022 - mdpi.com
In this study, we present a procedure to optimize a set of finite impulse response filter (FIR)
coefficients for digital pulse-amplitude measurement. Such an optimized filter is designed …

Estrazione di caratteristiche in tempo reale per sistemi di acquisizione dati senza trigger in esperimenti di fisica delle particelle

B Valinoti - 2023 - arts.units.it
Abstract The COmmon Muon and Proton Apparatus for Structure and Spectroscopy
(COMPASS) spectrometer at CERN is upgrading part of its detectors and data acquisition …

Low noise low power readout circuit for soft X ray detection

A Cerdeira-Estrada, A De Luca, A Cuttin… - Journal of applied …, 2003 - scielo.org.mx
A new low power CMOS ASIC for the detection of X-rays was optimized for low power and
low noise. Theoretical calculations and optimizations are presented and compared with …

Correction of the counting up number by dead time in detector systems for radiograph images

A Cerdeira E, A Cicuttin, A Cerdeira, M Estrada, A Luca - inis.iaea.org
[en] The effect of the dead time in a detection system by counting up of particles and the
contribution of this error in the final image resolution is analysed. It is given a statistical …

Correction of the counting up number by dead time in detector systems for radiograph images; Correccion del numero de conteos por tiempo muerto en sistemas …

A Cerdeira, A Cicuttin, A Cerdeira, M Estrada… - 2002 - osti.gov
Se analiza el efecto del tiempo muerto en un sistema de detection por conteo de particulas y
la contribution de este error en la resolution de la imagen final. Se da un criterio estadfstico …