Beam optics in nuclear microprobe: A review
AG Ponomarev, AA Ponomarov - … and Methods in Physics Research Section …, 2021 - Elsevier
The beam optics in a nuclear microprobe is considered on the basis of quality criteria for
focusing systems. In this consideration, empirical criteria with dominant chromatic or intrinsic …
focusing systems. In this consideration, empirical criteria with dominant chromatic or intrinsic …
Performance and application of heavy ion nuclear microbeam facility at the Nuclear Physics Institute in Řež, Czech Republic
O Romanenko, V Havranek, A Mackova… - Review of Scientific …, 2019 - pubs.aip.org
The Tandetron Laboratory of the Nuclear Physics Institute of the Czech Academy of
Sciences is equipped with five beam lines associated with a 3 MV tandem electrostatic …
Sciences is equipped with five beam lines associated with a 3 MV tandem electrostatic …
Adaptive neuro-fuzzy estimation of optimal lens system parameters
D Petković, NT Pavlović, S Shamshirband… - Optics and Lasers in …, 2014 - Elsevier
Due to the popularization of digital technology, the demand for high-quality digital products
has become critical. The quantitative assessment of image quality is an important …
has become critical. The quantitative assessment of image quality is an important …
The Sumy scanning nuclear microprobe: Design features and first tests
VE Storizhko, AG Ponomarev, VA Rebrov… - Nuclear Instruments and …, 2007 - Elsevier
A new scanning nuclear microprobe based on a single-ended 2MV Van de Graaff
accelerator has recently been designed and constructed at the Sumy Institute of Applied …
accelerator has recently been designed and constructed at the Sumy Institute of Applied …
Influence of the beam current density distribution on the spatial resolution of a nuclear microprobe
AA Ponomarov, VI Miroshnichenko… - Nuclear Instruments and …, 2009 - Elsevier
The paper discusses the effect of nonuniform distribution of the ion beam phase density on
the nuclear microprobe resolution. The deconvolution of the beam brightness distribution …
the nuclear microprobe resolution. The deconvolution of the beam brightness distribution …
One-stage probe-forming systems with quadrupole lenses excited by individual power supplies
AA Ponomarova, KI Melnik, GS Vorobjov… - Nuclear Instruments and …, 2011 - Elsevier
The work deals with the ion-optical characteristics of the probe-forming systems based on a
quadruplet of magnetic quadrupole lenses with four power supplies. The excitation of the …
quadruplet of magnetic quadrupole lenses with four power supplies. The excitation of the …
Optimization of the working distance of an ion microprobe-forming system
KI Melnik, DV Magilin, AG Ponomarev - Nuclear Instruments and Methods …, 2009 - Elsevier
A high-resolution ion microprobe necessitates the use of a small working distance (the
distance from the final quadrupole lens of a probe-forming system to the specimen) in order …
distance from the final quadrupole lens of a probe-forming system to the specimen) in order …
High resolution probe-forming system with spherical aberration correction for nuclear microprobe
AG Ponomarev, SV Kolinko… - Problems of Atomic …, 2023 - dspace.nbuv.gov.ua
A probe-forming system based on a separate orthomorphic quadruplet of magnetic
quadrupole lenses with a short working distance is considered, allowing the system …
quadrupole lenses with a short working distance is considered, allowing the system …
Ion microprobe improvements in Tandetron Laboratory NPI CAS: Numerical calculation
OV Romanenko, AG Ponomarev, A Macková… - Nuclear Instruments and …, 2019 - Elsevier
Ion scanning microprobe was implemented in the Tandetron Laboratory, Nuclear Physics
Institute of the Czech Academy of Sciences (NPI CAS) in Rez in 2009. Since then it has …
Institute of the Czech Academy of Sciences (NPI CAS) in Rez in 2009. Since then it has …
Протонный сканирующий микрозонд с интегрированной зондоформирующей системой
АГ Пономарев, ВА Ребров, НА Сайко, АБ Дудник… - Прикладная …, 2008 - elibrary.ru
На новом протонном сканирующем микрозонде на базе электростатического
ускорителя" Сокол" с максимальным напряжением 2 МВ начаты эксперименты в целях …
ускорителя" Сокол" с максимальным напряжением 2 МВ начаты эксперименты в целях …