A review of brachytherapy physical phantoms developed over the last 20 years: clinical purpose and future requirements

S Wilby, A Palmer, W Polak, A Bucchi - Journal of Contemporary …, 2021 - termedia.pl
Purpose This aim of this review paper was to present information on brachytherapy
phantoms developed over the last 20 years. It offers a starting point for designing new …

Dosimetric aspects of 166Ho brachytherapy biodegradable glass seed

SH Hosseini, M Enferadi, M Sadeghi - Applied Radiation and Isotopes, 2013 - Elsevier
The purpose of this study is to perform absorbed dose calculations based on Monte Carlo
simulations for a novel beta emitter bioglass Ho-166 seed which is proposed for treating …

Dosimetric characteristics of the brachytherapy sources based on Monte Carlo method

M Sadeghi, P Saidi, C Tenreiro - Applications of Monte Carlo …, 2011 - books.google.com
The term of brachytherapy, also known as “internal radiotherapy, sealed source
radiotherapy, curietherapy or endocurietherapy” is from Greek work brachy means short …

Thermoluminescent and Monte Carlo dosimetry of IR06‐brachytherapy source

P Saidi, M Sadeghi, SH Hosseini… - Journal of Applied …, 2011 - Wiley Online Library
This work presents experimental dosimetry results for a new brachytherapy seed, in
accordance with the AAPM TG‐43U1 recommendation that all new low‐energy interstitial …

Feasibility study of FLUKA Monte Carlo simulation for a beta-emitting brachytherapy source: dosimetric parameters of 142Pr glass seed

M Anjomrouz, MK Bakht, M Sadeghi - Journal of Radioanalytical and …, 2016 - Springer
A series of dosimetric calculations and modeling should be done before the clinical use of
any new brachytherapy source. In this work, the capability of the FLUKA Monte Carlo code to …

Experimental measurements and Monte Carlo calculations for 103Pd dosimetry of the 12 mm COMS eye plaque

P Saidi, M Sadeghi, C Tenreiro - Physica Medica, 2013 - Elsevier
Monte Carlo simulations and TLD dosimetry have been performed to determine the dose
distributions along the central axis of the 12 mm COMS eye plaques loaded with IRA1 …

Design and optimizing a novel ocular plaque brachytherapy with dual-core of 103Pd and 106Ru

M Sharifzadeh, TA Chiniforoush, M Sadeghi - Physica Medica, 2021 - Elsevier
In recent decades, eye plaques of brachytherapy have been extensively used as primary
treatment as well as a complementary treatment for ocular cancer. The purpose of this study …

Production of the 103Pd via Cyclotron and Preparation of the Brachytherapy Seed

P Saidi, M Sadeghi - Recent Techniques and Applications in …, 2020 - books.google.com
This study will briefly explain the production of 103Pd via cyclotron for brachytherapy use.
The excitation functions of 103Rh (p, n) 103Pd and 103Rh (d, 2n) 103Pd reactions were …

Monte Carlo evaluation of the dose sparing and dose enhancement by combination of Gd-infused tumor and 241Am source for an endocavitary brachytherapy …

M Fuentealba, M Santibáñez - Applied Radiation and Isotopes, 2020 - Elsevier
In this work, the benefits in terms of dose enhancement and dose sparing via radiation
shielding are evaluated, for a combined irradiation scheme with sources of 241 Am and …

[PDF][PDF] Monte Carlo dosimetry for 125-I eye plaque brachytherapy

M Sadeghi, A Farshadi, P Saidi… - J Nucl Med Radiat …, 2018 - researchgate.net
Monte Carlo Dosimetry for 125I Eye Plaque Brachytherapy Page 1 Volume 9 • Issue 4 •
1000367 J Nucl Med Radiat Ther, an open access journal ISSN: 2155-9619 Research Article …