A review of brachytherapy physical phantoms developed over the last 20 years: clinical purpose and future requirements
S Wilby, A Palmer, W Polak, A Bucchi - Journal of Contemporary …, 2021 - termedia.pl
Purpose This aim of this review paper was to present information on brachytherapy
phantoms developed over the last 20 years. It offers a starting point for designing new …
phantoms developed over the last 20 years. It offers a starting point for designing new …
Dosimetric aspects of 166Ho brachytherapy biodegradable glass seed
SH Hosseini, M Enferadi, M Sadeghi - Applied Radiation and Isotopes, 2013 - Elsevier
The purpose of this study is to perform absorbed dose calculations based on Monte Carlo
simulations for a novel beta emitter bioglass Ho-166 seed which is proposed for treating …
simulations for a novel beta emitter bioglass Ho-166 seed which is proposed for treating …
Dosimetric characteristics of the brachytherapy sources based on Monte Carlo method
The term of brachytherapy, also known as “internal radiotherapy, sealed source
radiotherapy, curietherapy or endocurietherapy” is from Greek work brachy means short …
radiotherapy, curietherapy or endocurietherapy” is from Greek work brachy means short …
Thermoluminescent and Monte Carlo dosimetry of IR06‐brachytherapy source
This work presents experimental dosimetry results for a new brachytherapy seed, in
accordance with the AAPM TG‐43U1 recommendation that all new low‐energy interstitial …
accordance with the AAPM TG‐43U1 recommendation that all new low‐energy interstitial …
Feasibility study of FLUKA Monte Carlo simulation for a beta-emitting brachytherapy source: dosimetric parameters of 142Pr glass seed
A series of dosimetric calculations and modeling should be done before the clinical use of
any new brachytherapy source. In this work, the capability of the FLUKA Monte Carlo code to …
any new brachytherapy source. In this work, the capability of the FLUKA Monte Carlo code to …
Experimental measurements and Monte Carlo calculations for 103Pd dosimetry of the 12 mm COMS eye plaque
Monte Carlo simulations and TLD dosimetry have been performed to determine the dose
distributions along the central axis of the 12 mm COMS eye plaques loaded with IRA1 …
distributions along the central axis of the 12 mm COMS eye plaques loaded with IRA1 …
Design and optimizing a novel ocular plaque brachytherapy with dual-core of 103Pd and 106Ru
In recent decades, eye plaques of brachytherapy have been extensively used as primary
treatment as well as a complementary treatment for ocular cancer. The purpose of this study …
treatment as well as a complementary treatment for ocular cancer. The purpose of this study …
Production of the 103Pd via Cyclotron and Preparation of the Brachytherapy Seed
This study will briefly explain the production of 103Pd via cyclotron for brachytherapy use.
The excitation functions of 103Rh (p, n) 103Pd and 103Rh (d, 2n) 103Pd reactions were …
The excitation functions of 103Rh (p, n) 103Pd and 103Rh (d, 2n) 103Pd reactions were …
Monte Carlo evaluation of the dose sparing and dose enhancement by combination of Gd-infused tumor and 241Am source for an endocavitary brachytherapy …
M Fuentealba, M Santibáñez - Applied Radiation and Isotopes, 2020 - Elsevier
In this work, the benefits in terms of dose enhancement and dose sparing via radiation
shielding are evaluated, for a combined irradiation scheme with sources of 241 Am and …
shielding are evaluated, for a combined irradiation scheme with sources of 241 Am and …
[PDF][PDF] Monte Carlo dosimetry for 125-I eye plaque brachytherapy
Monte Carlo Dosimetry for 125I Eye Plaque Brachytherapy Page 1 Volume 9 • Issue 4 •
1000367 J Nucl Med Radiat Ther, an open access journal ISSN: 2155-9619 Research Article …
1000367 J Nucl Med Radiat Ther, an open access journal ISSN: 2155-9619 Research Article …