Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning

IJ Chetty, B Curran, JE Cygler, JJ DeMarco… - Medical …, 2007 - Wiley Online Library
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …

Addendum to the AAPMˈs TG‐51 protocol for clinical reference dosimetry of high‐energy photon beams

M McEwen, L DeWerd, G Ibbott, D Followill… - Medical …, 2014 - Wiley Online Library
An addendum to the AAPMˈs TG‐51 protocol for the determination of absorbed dose to
water in megavoltage photon beams is presented. This addendum continues the procedure …

Dose calculation for photon‐emitting brachytherapy sources with average energy higher than 50 keV: report of the AAPM and ESTRO

J Perez‐Calatayud, F Ballester, RK Das… - Medical …, 2012 - Wiley Online Library
Purpose: Recommendations of the American Association of Physicists in Medicine (AAPM)
and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for …

Efficiency improvements for ion chamber calculations in high energy photon beams

J Wulff, K Zink, I Kawrakow - Medical physics, 2008 - Wiley Online Library
This article presents the implementation of several variance reduction techniques that
dramatically improve the simulation efficiency of ion chamber dose and perturbation factor …

Benchmarking brachydose: voxel based EGSnrc Monte Carlo calculations of TG‐43 dosimetry parameters

REP Taylor, G Yegin, DWO Rogers - Medical physics, 2007 - Wiley Online Library
In this study, BrachyDose, a recently developed EGSnrc Monte Carlo code for rapid
brachytherapy dose calculations, has been benchmarked by reproducing previously …

Total scatter factors of small beams: a multidetector and Monte Carlo study

P Francescon, S Cora, C Cavedon - Medical physics, 2008 - Wiley Online Library
The scope of this study was to estimate total scatter factors of the three smallest collimators
of the Cyberknife radiosurgery system (5–10 mm in diameter), combining experimental …

An EGSnrc Monte Carlo‐calculated database of TG‐43 parameters

REP Taylor, DWO Rogers - Medical physics, 2008 - Wiley Online Library
Monte Carlo methods are used to calculate a complete TG‐43 dosimetry parameter data set
for 27 low‐energy photon emitting brachytherapy sources (18 and 9). All Monte Carlo …

EGSnrc Monte Carlo calculated dosimetry parameters for and brachytherapy sources

REP Taylor, DWO Rogers - Medical physics, 2008 - Wiley Online Library
This study presents the results of EGSnrc Monte Carlo calculations of the dose distribution
surrounding a high dose rate brachytherapy source and 14 high dose rate and pulsed dose …

Relative dosimetry with an MR‐linac: response of ion chambers, diamond, and diode detectors for off‐axis, depth dose, and output factor measurements

DJ O'Brien, J Dolan, S Pencea, N Schupp… - Medical …, 2018 - Wiley Online Library
Purpose The purpose of this study was to acquire beam data for an MR‐linac, with and
without a 1.5 T magnetic field, by using a variety of commercially available detectors to …

Monte-Carlo-based perturbation and beam quality correction factors for thimble ionization chambers in high-energy photon beams

J Wulff, JT Heverhagen, K Zink - Physics in Medicine & Biology, 2008 - iopscience.iop.org
This paper presents a detailed investigation into the calculation of perturbation and beam
quality correction factors for ionization chambers in high-energy photon beams with the use …