Reintervention rate in glaucoma filtering surgery: A systematic review and meta-analysis

P Marolo, M Reibaldi, M Fallico… - European Journal …, 2022 - journals.sagepub.com
Purpose Reintervention rate is an important factor impacting on patients, surgeons, and
society. To date, only a few studies have focused on this topic. For this reason, a systematic …

Comparison of bleeding complications after pediatric kidney biopsy between intravenous sedation and general anesthesia: a nationwide cohort study

A Okada, K Ikeda Kurakawa, Y Harita, A Shimizu… - BMC pediatrics, 2023 - Springer
Background An increasing number of studies are evaluating the safety of intravenous
sedation compared with that of general anesthesia; however, data on bleeding …

Ex-PRESS Implantation versus Trabeculectomy for Long-Term Maintenance in Patients with Open-Angle Glaucoma

K Tokumo, N Okada, H Onoe, K Komatsu… - Clinical …, 2023 - Taylor & Francis
Purpose To compare the efficacy of Ex-PRESS implantation (EXP) with that of
trabeculectomy (TLE) with mitomycin C for maintaining low target intraocular pressure (IOP) …

Comparison of surgical outcomes between initial trabeculectomy and Ex-PRESS in terms of achieving an intraocular pressure below 15 and 18 mmHg: a retrospective …

S Nakakura, R Asaoka - Eye and Vision, 2022 - Springer
Background To evaluate the postoperative outcomes of initial trabeculectomy (Trab) and Ex-
PRESS (EX) in terms of achieving an intraocular pressure (IOP) below 15 and 18 mmHg …

One-year costs of incisional glaucoma surgery and laser therapy

A Fujita, R Sakata, Y Hashimoto, H Matsui… - Annals of Clinical …, 2023 - jstage.jst.go.jp
BACKGROUND This study aimed to calculate one-year total costs of incisional glaucoma
surgery and laser therapy in a real-world clinical setting. METHODS We conducted a …

Long-Term Changes in Corneal Endothelial Cell Density after Ex-PRESS Implantation: A Contralateral Eye Study

X Ren, J Wang, X Li, L Wu - Journal of Clinical Medicine, 2022 - mdpi.com
Our purpose is to evaluate long-term changes in corneal endothelial cells after Ex-PRESS
shunt implantation for the treatment of glaucoma in Chinese patients by comparison with the …

Ex-PRESS implantation versus trabeculectomy for long-term maintenance of low intraocular pressure in patients with open angle glaucoma

K Tokumo, N Okada, H Onoe, K Komatsu, S Masuda… - medRxiv, 2022 - medrxiv.org
Purpose To compare the efficacy of Ex-PRESS implantation to trabeculectomy with
mitomycin C, for maintaining low target intraocular pressure (IOP) in patients with open …

Risk factors for Ex-Press® surgery failure

M Otsuka, N Tojo, A Hayashi - International Ophthalmology, 2023 - Springer
Purpose To investigate the risk factors for Ex-Press®(EXP) surgery failure. Patients and
methods This was a retrospective non-randomized study of 98 patients who had undergone …

Application of EX-PRESS implants type P-50 in the surgical treatment of open angle glaucoma in pseudophakic eyes

A Duchowska, M Kucharczyk-Pośpiech… - Klinika …, 2023 - publicum.umed.lodz.pl
Introduction To report the efficacy and safety of the EX-PRESS Glaucoma Filtration Device
type P-50 in pseudophakic eyes with primary or secondary open angle glaucoma. Material …

Ex-PRESS implantation versus trabeculectomy for long-term maintenance of low intraocular pressure in open angle glaucoma patients

K Tokumo, N Okada, H Onoe, K Komatsu, S Masuda… - 2022 - researchsquare.com
Purpose To compare the efficacy of Ex-PRESS implantation (EXP) to trabeculectomy (TLE)
with mitomycin C, for maintaining low target intraocular pressure (IOP) in patients with open …