[HTML][HTML] Tribology of medical devices
ZM Jin, J Zheng, W Li, ZR Zhou - Biosurface and Biotribology, 2016 - Elsevier
Importance of tribology in a number of medical devices and surgical instruments is reviewed,
including artificial joints, artificial teeth, dental implants and orthodontic appliances …
including artificial joints, artificial teeth, dental implants and orthodontic appliances …
[PDF][PDF] 第3 代人工心脏泵研究进展及应用
刘鑫, 曲洪一, 王聪, 刘建华, 王秋良 - 中国生物医学工程学报, 2022 - cjbme.csbme.org
心力衰竭死亡率极高ꎬ 患病数量持续攀升ꎬ 是当今医学界面临的共同难题ꎬ
人工心脏泵是众多心衰患者延长生存期最后的希望和最有效的途径ꎮ 第3 …
人工心脏泵是众多心衰患者延长生存期最后的希望和最有效的途径ꎮ 第3 …
Blood sealing properties of magnetic fluid seals
J Tomioka, N Miyanaga - Tribology International, 2017 - Elsevier
Shaft seals for rotary blood pumps have strong demands for low friction, very little leakage,
and long-term use. Magnetic fluid seals have attracted attention as promising candidates for …
and long-term use. Magnetic fluid seals have attracted attention as promising candidates for …
Real-time, non-invasive thrombus detection in an extracorporeal circuit using micro-optical thrombus sensors
N Morita, D Sakota, A Oota-Ishigaki… - … Journal of Artificial …, 2021 - journals.sagepub.com
Introduction: Real-time, non-invasive monitoring of thrombus formation in extracorporeal
circuits has yet to be achieved. To address the challenges of conventional optical thrombus …
circuits has yet to be achieved. To address the challenges of conventional optical thrombus …
Feasibility of the optical imaging of thrombus formation in a rotary blood pump by near‐infrared light
Blood coagulation is one of the primary concerns when using mechanical circulatory support
devices such as blood pumps. Noninvasive detection and imaging of thrombus formation is …
devices such as blood pumps. Noninvasive detection and imaging of thrombus formation is …
The influence of impeller geometries on hemolysis in bearingless centrifugal pumps
P Puentener, M Schuck, JW Kolar - IEEE Open Journal of …, 2020 - ieeexplore.ieee.org
Goal: The importance of the main impeller design parameters in bearingless centrifugal
pumps with respect to hemolysis for cardiopulmonary bypass (CPB) and extracorporeal …
pumps with respect to hemolysis for cardiopulmonary bypass (CPB) and extracorporeal …
Effects of eccentric impeller position on radial passive stability in a magnetically levitated centrifugal blood pump with a double volute
S Shida, T Masuzawa, M Osa, R Sato - Advanced Biomedical …, 2018 - jstage.jst.go.jp
Abstract Evaluation of the impeller radial stability is important from the bioengineering point
of view in the development of mechanical circulatory support devices (MCSDs) for safer use …
of view in the development of mechanical circulatory support devices (MCSDs) for safer use …
[HTML][HTML] Optical aggregometry of red blood cells associated with the blood-clotting reaction in extracorporeal circulation support
The aggregability of red blood cell (RBCs) is associated with the contribution of plasma
proteins, such as fibrinogen and lipoproteids, to blood-clotting. Hence, we hypothesized that …
proteins, such as fibrinogen and lipoproteids, to blood-clotting. Hence, we hypothesized that …
Spiral groove bearing design for improving plasma skimming in rotary blood pumps
M Jiang, W Hijikata - Journal of Artificial Organs, 2024 - Springer
High-efficiency plasma skimming is hopeful to prevent hemolysis inside spiral groove
bearings (SGBs) because it can exclude red blood cells from the ridge gap with a high shear …
bearings (SGBs) because it can exclude red blood cells from the ridge gap with a high shear …
Design and hemocompatibility analysis of a double‐suction injection suspension blood pump using computational fluid dynamics methods
Y Wu, L Zhu, Y Luo - Artificial Organs, 2017 - Wiley Online Library
The blood pump has become a possible solution to heart diseases. For the prevention of
device failure and hemocompatibility problems, a rotary pump with suspended bearing is a …
device failure and hemocompatibility problems, a rotary pump with suspended bearing is a …