Intumescent coatings used for the fire-safe design of steel structures: A review
A Lucherini, C Maluk - Journal of Constructional Steel Research, 2019 - Elsevier
The mainstream use of intumescent coatings for the design of fire-safe steel structures has
fostered extensive research into the development of effective intumescent coatings and the …
fostered extensive research into the development of effective intumescent coatings and the …
Fire resistance of reinforced concrete and steel structures
V Sadkovyi, V Andronov, O Semkiv… - Fire Resistance of …, 2021 - papers.ssrn.com
FIRE RESISTANCE OF REINFORCED CONCRETE AND STEEL STRUCTURES Page 1 Edited
by Volodymyr Sadkovyi, Evgenіy Rybka, Yurii Otrosh FIRE RESISTANCE OF REINFORCED …
by Volodymyr Sadkovyi, Evgenіy Rybka, Yurii Otrosh FIRE RESISTANCE OF REINFORCED …
Review of heat exposure equipment and in-situ characterisation techniques for intumescent coatings
JAH Dreyer, CE Weinell, K Dam-Johansen, S Kiil - Fire Safety Journal, 2021 - Elsevier
The performance of commercial intumescent coatings is assessed by industrial norms and
standards with clearly defined experimental conditions. In contrast, academic research on …
standards with clearly defined experimental conditions. In contrast, academic research on …
Experimental study of the performance of intumescent coatings exposed to standard and non-standard fire conditions
Three different experimental setups corresponding to three different fire scenarios were
used to investigate how different heating conditions and heating rates affect the behaviour of …
used to investigate how different heating conditions and heating rates affect the behaviour of …
A heat-transfer rate inducing system (H-TRIS) test method
A novel fire testing method, named the Heat-Transfer Rate Inducing System (H-TRIS), is
presented and described in this paper. The method directly controls the thermal boundary …
presented and described in this paper. The method directly controls the thermal boundary …
Assessing the onset of swelling for thin intumescent coatings under a range of heating conditions
A Lucherini, C Maluk - Fire Safety Journal, 2019 - Elsevier
In the past decades, the steel industry has experienced a rapid growth in the use of
intumescent coatings for protecting load-bearing steel structures in the event of a fire. The …
intumescent coatings for protecting load-bearing steel structures in the event of a fire. The …
Tests on intumescent paints for fire protection of existing steel structures
A Bilotta, D de Silva, E Nigro - Construction and Building Materials, 2016 - Elsevier
Intumescent coatings (ic) are often used on steel structures to reduce the heating during a
fire when the structural, aesthetic, and architectural value of the structural members should …
fire when the structural, aesthetic, and architectural value of the structural members should …
Exploring the fire behaviour of thin intumescent coatings used on timber
A Lucherini, QS Razzaque, C Maluk - Fire Safety Journal, 2019 - Elsevier
The study presented herein describes an exploratory investigation on the fire performance of
intumescent coatings used on timber elements. Timber samples, uncoated or coated with …
intumescent coatings used on timber elements. Timber samples, uncoated or coated with …
Approach for modelling thermal properties of intumescent coating applied on steel members
D de Silva, A Bilotta, E Nigro - Fire Safety Journal, 2020 - Elsevier
Thin intumescent coating (IC) are nowadays the dominant passive system used to protect
structural steel in case of fire. This paper proposes a general procedure for modelling …
structural steel in case of fire. This paper proposes a general procedure for modelling …
Numerical heat transfer model for swelling intumescent coatings during heating
This research study presents a heat transfer model aimed at estimating the thermal and
physical response of intumescent coatings. The numerical model is inspired by the …
physical response of intumescent coatings. The numerical model is inspired by the …