Developments in control systems for rotary left ventricular assist devices for heart failure patients: a review
From the moment of creation to the moment of death, the heart works tirelessly to circulate
blood, being a critical organ to sustain life. As a non-stopping pumping machine, it operates …
blood, being a critical organ to sustain life. As a non-stopping pumping machine, it operates …
Physiologic outcome of varying speed rotary blood pump support algorithms: a review study
S Bozkurt - Australasian physical & engineering sciences in …, 2016 - Springer
Rotary blood pumps have the potential to become a viable long-term treatment option for the
heart failure patients to bridge to transplantation or destination therapy. However, these …
heart failure patients to bridge to transplantation or destination therapy. However, these …
In vivo evaluation of physiologic control algorithms for left ventricular assist devices based on left ventricular volume or pressure
G Ochsner, MJ Wilhelm, R Amacher, A Petrou… - Asaio …, 2017 - journals.lww.com
Turbodynamic left ventricular assist devices (LVADs) provide a continuous flow depending
on the speed at which the pump is set, and do not adapt to the changing requirements of the …
on the speed at which the pump is set, and do not adapt to the changing requirements of the …
Simulation of dilated heart failure with continuous flow circulatory support
Lumped parameter models have been employed for decades to simulate important
hemodynamic couplings between a left ventricular assist device (LVAD) and the native …
hemodynamic couplings between a left ventricular assist device (LVAD) and the native …
Emulation of ventricular suction in a hybrid mock circulation
G Ochsner, R Amacher… - 2013 european control …, 2013 - ieeexplore.ieee.org
Ventricular suction occurs when a turbodynamic ventricular assist device (VAD) tries to
pump more blood from the ventricle than is available. Suction causes a stagnation of the …
pump more blood from the ventricle than is available. Suction causes a stagnation of the …
Robust aortic valve non‐opening detection for different cardiac conditions
In recent years, extensive studies have been conducted in the area of pumping state
detection for implantable rotary blood pumps. However, limited studies have focused on …
detection for implantable rotary blood pumps. However, limited studies have focused on …
Novel solutions for patient monitoring and mechanical circulatory support device control
Monitoring of the interaction between the circulatory system and the pump is essential for
postoperative and ambulatory care of VAD patients. VAD monitoring gives important …
postoperative and ambulatory care of VAD patients. VAD monitoring gives important …
Iterative learning control of medical applications
Natürliche Kontrollmechanismen bilden die Grundlage z. B. für die Aufrechterhaltung der
Homöostase. Durch den Alterungsprozess, Krankheiten oder Unfälle kann ihre …
Homöostase. Durch den Alterungsprozess, Krankheiten oder Unfälle kann ihre …
Artificial organs 2011: A year in review
PS Malchesky - Artificial Organs, 2012 - Wiley Online Library
Abstract In this Editor's Review, articles published in 2011 are organized by category and
briefly summarized. As the official journal of The International Federation for Artificial …
briefly summarized. As the official journal of The International Federation for Artificial …
[PDF][PDF] Intelligent rotary blood pumps with physiological response
A Petrou - 2018 - research-collection.ethz.ch
The heart constitutes a vital organ of the human body, as it pumps blood through the vessels
of the circulatory system to provide oxygen, nutrients and support the metabolism process …
of the circulatory system to provide oxygen, nutrients and support the metabolism process …