Cable-in-conduit conductors: lessons from the recent past for future developments with low and high temperature superconductors
L Muzzi, G De Marzi, A Di Zenobio… - Superconductor …, 2015 - iopscience.iop.org
We review progress in the design of high field superconducting cable-in-conduit conductors
(CICCs) for fusion applications, with special attention to the results of recent key …
(CICCs) for fusion applications, with special attention to the results of recent key …
Effect of transverse compressive monotonic and cyclic loading on the performance of superconducting CORC® cables and wires
DC Van Der Laan, DM McRae… - … Science and Technology, 2018 - iopscience.iop.org
Superconducting CORC® cables and wires have become practical conductors for use in
high-field magnets for fusion machines and particle accelerators by demonstrating their …
high-field magnets for fusion machines and particle accelerators by demonstrating their …
Results of the TF conductor performance qualification samples for the ITER project
The performance of the toroidal field (TF) magnet conductors for the ITER machine are
qualified by a short full-size sample (4 m) current sharing temperature (T cs) test in the …
qualified by a short full-size sample (4 m) current sharing temperature (T cs) test in the …
The n2EDM experiment at the Paul Scherrer institute
We present the new spectrometer for the neutron electric dipole moment (nEDM) search at
the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum …
the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum …
Review of experimental results and models for AC losses in the ITER PF and CS conductors
A Torre, P Bauer, JL Duchateau… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
During the years of ITER conductors qualification and production, samples from all domestic
agencies were tested. Some of these tests were focused on characterizing the AC losses …
agencies were tested. Some of these tests were focused on characterizing the AC losses …
Finite element modelling of cable-in-conduit conductors
H Bajas, D Durville, A Devred - Superconductor Science and …, 2012 - iopscience.iop.org
Abstract The ITER (International Thermonuclear Experimental Reactor) cable-in-conduit
conductors (CICCs) are subjected to high thermal and electromagnetic cyclic loadings …
conductors (CICCs) are subjected to high thermal and electromagnetic cyclic loadings …
Internal Tin Conductors Engineered for Fusion and Particle Accelerator Applications
JA Parrell, Y Zhang, MB Field… - IEEE Transactions …, 2009 - ieeexplore.ieee.org
The critical current density (J c) of Nb 3 Sn strand has been significantly improved over the
last several years. For most magnet applications, high J c internal tin has displaced bronze …
last several years. For most magnet applications, high J c internal tin has displaced bronze …
Results of a new generation of ITER TF conductor samples in SULTAN
P Bruzzone, B Stepanov, R Wesche… - IEEE transactions on …, 2008 - ieeexplore.ieee.org
A new generation of ITER TF conductor samples has been assembled and tested in
SULTAN in 2007 following a common procedure agreed among the ITER parties. The test …
SULTAN in 2007 following a common procedure agreed among the ITER parties. The test …
Optimization of ITER Nb3Sn CICCs for coupling loss, transverse electromagnetic load and axial thermal contraction
A Nijhuis, EPA Van Lanen… - … Science and Technology, 2011 - iopscience.iop.org
The ITER cable-in-conduit conductors (CICCs) are built up from sub-cable bundles, wound
in different stages, which are twisted to counter coupling loss caused by time-changing …
in different stages, which are twisted to counter coupling loss caused by time-changing …
Methods, accuracy and reliability of ITER conductor tests in SULTAN
P Bruzzone, B Stepanov, R Wesche… - IEEE transactions on …, 2009 - ieeexplore.ieee.org
In the last decade, a large number of high current, force flow superconductors have been
tested as short length samples in the SULTAN facility. The object of the test ranged over …
tested as short length samples in the SULTAN facility. The object of the test ranged over …