Effect of reactive power characteristic of offshore wind power plant on low-frequency stability
Oscillation phenomena of offshore wind power plant (OWPP) in a wide frequency range can
be caused due to impedance interactions between grid-connected inverters (GCIs) and …
be caused due to impedance interactions between grid-connected inverters (GCIs) and …
A gray-box hierarchical oscillatory instability source identification method of multiple-inverter-fed power systems
This article presents a gray-box hierarchical instability source identification method of
multiple-inverter-fed power systems, which enables stability analysis at system, component …
multiple-inverter-fed power systems, which enables stability analysis at system, component …
Impedance-decoupled modeling method of multiport transmission network in inverter-fed power plant
This article presents an impedance-decoupled modeling method of multiport transmission
network in an inverter-fed power plant, which is able to simplify modeling and stability …
network in an inverter-fed power plant, which is able to simplify modeling and stability …
[HTML][HTML] Impact of Reactive Current and Phase-Locked Loop on Converters in Grid Faults
Z Zhang, R Schuerhuber - Energies, 2023 - mdpi.com
The precise control of output power by grid-connected converters relies on the correct
identification and tracking of a grid voltage's phase at the converter terminal. During severe …
identification and tracking of a grid voltage's phase at the converter terminal. During severe …
DQ impedance‐decoupled network model‐based stability analysis of offshore wind power plant under weak grid conditions
This study presents a dq impedance‐decoupled network modelling method of offshore wind
power plant (OWPP) for stability analysis. DQ impedance frequency responses of grid …
power plant (OWPP) for stability analysis. DQ impedance frequency responses of grid …
DQ impedance reshaping of three-phase power-controlled grid-connected inverter for low-frequency stability improvement under weak grid condition
Phase-locked loop (PLL) is commonly used to synchronize the phase angle of the injected
current of voltage source grid-connected inverters (GCIs) with that of the voltage at point of …
current of voltage source grid-connected inverters (GCIs) with that of the voltage at point of …
Current and Voltage Scaling for Maximum Transferable Active Power Improvement of Weak-Grid-Tied Grid-Following Inverters
The grid-following inverter's dq admittance model manifests a negative resistance in the low-
frequency range due to the phase-locked loop, potentially leading to low-frequency …
frequency range due to the phase-locked loop, potentially leading to low-frequency …
A modified dq impedance model of three-phase grid-connected inverter-grid system considering coupling between inverter and grid
This paper presents a modified dq impedance model of the three-phase voltage source grid-
connected inverter (GCI)-grid system considering coupling effect between GCI part and grid …
connected inverter (GCI)-grid system considering coupling effect between GCI part and grid …
Frequency scanning-based contributions identification of current control loop and PLL on DQ impedance characteristics of three-phase grid-connected inverter
Complex space vector and complex transfer function theory is used to theoretically establish
the dq impedance model of current-controlled grid-connected inverter (GCI) with considering …
the dq impedance model of current-controlled grid-connected inverter (GCI) with considering …