[图书][B] Encyclopedia of medical devices and instrumentation

JG Webster - 1990 - dl.acm.org
From the Publisher: This objective, referenced collection of over 300 articles will cover every
aspect of medical devices and instrumentation in four volumes, totalling about 3,000 pages …

Method and apparatus for dynamized spinal stabilization

RA Dixon, DJ Hackman - US Patent 6,645,207, 2003 - Google Patents
An improved device and a method for stabilizing lumbar vertebrae in a human spine for the
purpose of fixing the vertebra with respect to other vertebra and with respect to other parts of …

Biomechanical rigidity of an all-polyetheretherketone anterior thoracolumbar spinal reconstruction construct: an in vitro corpectomy model

SM Moon, A Ingalhalikar, JM Highsmith, AR Vaccaro - The Spine Journal, 2009 - Elsevier
BACKGROUND CONTEXT: Polyetheretherketone (PEEK) is gaining favor as a spinal
implant material for interbody and corpectomy cages as well as stabilizing rods. However …

Role of mechanical compression on bone regeneration around a particulate bone graft material: an experimental study in rabbit calvaria

GE Romanos, RA Delgado‐Ruiz… - Clinical oral implants …, 2018 - Wiley Online Library
Purpose This experimental study was designed to analyze the effect of different compressive
forces on the bone regeneration around a particulate bone graft material. Material and …

Comparison of the biomechanics of hydroxyapatite and polymethylmethacrylate vertebroplasty in a cadaveric spinal compression fracture model

PW Hitchon, V Goel, J Drake, D Taggard… - … of Neurosurgery: Spine, 2001 - thejns.org
Object. Polymethylmethacrylate (PMMA) has long been used in the stabilization and
reconstruction of traumatic and pathological fractures of the spine. Recently, hydroxyapatite …

In vitro biomechanical analysis of three anterior thoracolumbar implants

PW Hitchon, VK Goel, TN Rogge, JC Torner… - … of Neurosurgery: Spine, 2000 - thejns.org
Object. The goal of this study was to evaluate the comparative efficacy of three commonly
used anterior thoracolumbar implants: the anterior thoracolumbar locking plate (ATLP), the …

Biomechanical analysis of anterior versus posterior instrumentation following a thoracolumbar corpectomy

SV Viljoen, NADV Watson, NM Grosland… - … of Neurosurgery: Spine, 2014 - thejns.org
Object The objective of this study was to evaluate the biomechanical properties of lateral
instrumentation compared with short-and long-segment pedicle screw constructs following …

An in vitro biomechanical comparison of single-rod, dual-rod, and dual-rod with transverse connector in anterior thoracolumbar instrumentation

CG Reddy, M Magnetta, NS Dahdaleh, M Demmer… - …, 2012 - journals.lww.com
BACKGROUND: After thoracolumbar corpectomy, standard anterolateral instrumentation
may consist of dual rods with cross-connectors. However, when the vertebral bodies are …

Biomechanical analysis of stabilization for thoracolumbar anterior spinal failure caused by osteolytic lesions, a finite element comparison of direct lateral corpectomy …

E Nevzati, AG Oliver, C Rhoads, W Jens-Peter… - The Spine Journal, 2024 - Elsevier
Abstract Background Context Osteolytic lesions caused by infection or metastatic disease of
the spine can induce instability. Different surgical strategies are available to restore stability …

Compression and contact area of anterior strut grafts in spinal instrumentation: a biomechanical study

A Pizanis, JH Holstein, F Vossen, M Burkhardt… - BMC Musculoskeletal …, 2013 - Springer
Background Anterior bone grafts are used as struts to reconstruct the anterior column of the
spine in kyphosis or following injury. An incomplete fusion can lead to later correction losses …